The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Oxygen Reduction Reaction Measurements on Platinum Electrocatalysts Utilizing Rotating Disk Electrode Technique: I. Impact of Impurities, Measurement Protocols and Applied Corrections
Open accessAbstract
The rotating disk electrode (RDE) technique is being extensively used as a screening tool to estimate the activity of novel PEMFC electrocatalysts synthesized in lab-scale (mg) quantities.Discrepancies in measured activity attributable to glassware and electrolyte impurity levels, as well as conditioning, protocols and corrections are prevalent in the literature.The electrochemical response to a broad spectrum of commercially sourced perchloric acid and the effect of acid molarity on impurity levels and solution resistance were also assessed.Our findings reveal that an area specific activity (SA) exceeding 2.0 mA/cm 2 (20 mV/s, 25 • C, 100 kPa, 0.1 M HClO 4 ) for polished poly-Pt is an indicator of impurity levels that do not impede the accurate measurement of the ORR activity of Pt based catalysts.After exploring various conditioning protocols to approach maximum utilization of the electrochemical area (ECA) and peak ORR activity without introducing catalyst degradation, an investigation of measurement protocols for ECA and ORR activity was conducted.Down-selected protocols were based on the criteria of reproducibility, duration of experiments, impurity effects and magnitude of pseudo-capacitive background correction.Statistical reproducibility of ORR activity for poly-Pt and Pt supported on high surface area carbon was demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gasteiger, H. A., Kocha, S. S., Sompalli, B., & Wagner, F. T. (2005) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2004.06.021 · Cited by 4,876
Self-citationImproved Oxygen Reduction Activity on Pt 3 Ni(111) via Increased Surface Site Availability
Stamenkovic, V. R., Fowler, B., Mun, B. S., Wang, G., Ross, P. N., Lucas, C. A., & Marković, N. M. (2007) · Science · doi:10.1126/science.1135941 · Cited by 4,421
Trends in electrocatalysis on extended and nanoscale Pt-bimetallic alloy surfaces
Stamenkovic, V. R., Mun, B. S., Arenz, M., Mayrhofer, K. J. J., Lucas, C. A., Wang, G., Ross, P. N., & Markovic, N. M. (2007) · Nature Materials · doi:10.1038/nmat1840 · Cited by 3,252
Platinum-Based Oxygen Reduction Electrocatalysts
Wu, J., & Yang, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300359w · Cited by 1,050
Oxygen Reduction on Carbon-Supported Pt−Ni and Pt−Co Alloy Catalysts
Paulus, U. A., Wokaun, A., Scherer, G. G., Schmidt, T. J., Stamenkovic, V., Radmilovic, V., Markovic, N. M., & Ross, P. N. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp013442l · Cited by 954
Markovic, N., Gasteiger, H., & Ross, P. N. (1997) · Journal of The Electrochemical Society · doi:10.1149/1.1837646 · Cited by 564
Kinetics of O 2 Reduction on a Pt Electrode Covered with a Thin Film of Solid Polymer Electrolyte
Zecevic, S. K., Wainright, J. S., Litt, M. H., Gojkovic, S. L., & Savinell, R. F. (1997) · Journal of The Electrochemical Society · doi:10.1149/1.1837946 · Cited by 209
Liu, Z., Jackson, G. S., & Eichhorn, B. W. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200907019 · Cited by 192
Oxygen Reduction Activity of PtxNi1-x Alloy Nanoparticles on Multiwall Carbon Nanotubes
Kim, J., Lee, S. W., Carlton, C., & Shao-Horn, Y. (2011) · Electrochemical and Solid-State Letters · doi:10.1149/1.3613677 · Cited by 27
Cited by
Recent Advances in Electrocatalysts for Oxygen Reduction Reaction
Shao, M., Chang, Q., Dodelet, J.-P., & Chenitz, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00462 · Cited by 3,903
Shih, A. J., Monteiro, M. C. O., Dattila, F., Pavesi, D., Philips, M., da Silva, A. H. M., Vos, R. E., Ojha, K., Park, S., van der Heijden, O., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00164-0 · Cited by 521
Lazaridis, T., Stühmeier, B. M., Gasteiger, H. A., & El-Sayed, H. A. (2022) · Nature Catalysis · doi:10.1038/s41929-022-00776-5 · Cited by 396
Wang, M., Park, J. H., Kabir, S., Neyerlin, K. C., Kariuki, N. N., Lv, H., Stamenkovic, V. R., Myers, D. J., Ulsh, M., & Mauger, S. A. (2019) · ACS Applied Energy Materials · doi:10.1021/acsaem.9b01037 · Cited by 192
Wang, C., An, C., Qin, C., Gomaa, H., Deng, Q., Wu, S., & Hu, N. (2022) · Nanomaterials · doi:10.3390/nano12142480 · Cited by 39
Metadata
- Authors
- Shinozaki, K., Zack, J. W., Richards, R. M., Pivovar, B. S., & Kocha, S. S.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2015
- Volume
- 162
- Issue
- 10
- Pages
- F1144-F1158
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2140058815
- Cited by
- 353
- References
- 9
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen Reduction Reaction Measurements on Platinum Electrocatalysts Utilizing Rotating Disk Electrode Technique: I. Impact of Impurities, Measurement Protocols and Applied Corrections. https://app.cochat.ai/papers/10.1149/2.1071509jes
- The paper
- Shinozaki, K., Zack, J. W., Richards, R. M., Pivovar, B. S., & Kocha, S. S. (2015). Oxygen Reduction Reaction Measurements on Platinum Electrocatalysts Utilizing Rotating Disk Electrode Technique: I. Impact of Impurities, Measurement Protocols and Applied Corrections. Journal of The Electrochemical Society. https://doi.org/10.1149/2.1071509jes
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.