Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record.

Interaction of two electrical pacemakers in muscularis of canine proximal colon

Smith, T. K., Reed, J. B., Sanders, K. M.·1987·American Journal of Physiology-Cell Physiology

Abstract

Experiments were performed to determine the source of the 20 cycles/min electrical oscillation commonly seen in colonic electrical records, the influence of the 20 cycles/min rhythm on the circular and longitudinal muscle layers, and the interactions between the 20 cycles/min rhythm and slow waves in circular muscle cells. Cross-sectional muscle preparations of the canine proximal colon were used to allow impalement of cells at any point through the thickness of the muscularis. Intracellular recordings from circular muscle cells clearly showed the two characteristic pacemaker frequencies in the colon (6 cycles/min slow waves; 20 cycles/min oscillations). The 20 cycles/min oscillations were recorded from longitudinal and circular muscle cells. Their amplitudes were greatest at the myenteric border. In the longitudinal layer the 20 cycles/min events initiated action potentials; in circular muscle the 20 cycles/min events summed with slow waves. Simultaneous recordings from circular and longitudinal cells across the myenteric border demonstrated that events in the two layers were usually in phase, suggesting that the two layers are electrically coupled and are paced by a common pacemaker. The amplitude of the 20 cycles/min events decayed with distance from the myenteric border in both circular and longitudinal muscles. The data demonstrate that two discrete populations of pacemaker cells generate the spontaneous electrical activity in the colon. Both events appear to passively spread through the circular muscle. It is the summation of these events that appears to serve as the signal for excitation-contraction coupling in circular muscle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpcell.1987.252.3.c290

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Smith, T. K., Reed, J. B., & Sanders, K. M.
Venue
American Journal of Physiology-Cell Physiology
Published
1987-03-01
Volume
252
Issue
3
Pages
C290-C299
ISSN
  • 0363-6143 (ISSN-L)
  • 1522-1563
OpenAlex
W1777437113
Cited by
165
References
0
FWCI
5.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interaction of two electrical pacemakers in muscularis of canine proximal colon. https://app.cochat.ai/papers/10.1152/ajpcell.1987.252.3.c290
The paper
Smith, T. K., Reed, J. B., & Sanders, K. M. (1987). Interaction of two electrical pacemakers in muscularis of canine proximal colon. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1987.252.3.c290

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.