The DOI matches its Crossref record.
Intracellular pH measurement using single excitation-dual emission fluorescence ratios
Abstract
In the present paper, laser spectroscopy was used to evaluate the utility of a new fluorochrome, carboxyseminaphthorhodafluor-1 (Snarf-1), for single excitation-dual emission ratio measurement of intracellular pH (pHi). The emission spectrum of Snarf-1 showed clear pH-dependent shifts, and emission ratios calculated from the 640 and 587 nm maxima were a sensitive indicator of pH. When irradiated in Cunningham chambers, solutions of Snarf-1 were rapidly bleached, and at pH 7.3 or higher, this bleaching led to a decrease in the 640/587 nm emission ratio. These ratio changes were also observed in intracellular measurements on lens embryonic epithelial cells under conditions in which the entrapped dye was rapidly bleached. As the laser dosage was reduced (by increasing the step size between sample points), bleaching could be reduced to very low levels, and under these conditions, the ratio remained constant. Snarf-1 loaded into lens epithelial explants was calibrated intracellularly using nigericin. Intracellular calibration curves were shifted to more alkaline values than in vitro curves. Intracellular calibration allowed estimates of pHi that were in reasonable agreement with previously published values for lens tissue. Potential artifacts arising from differential photobleaching and intracellular-in vitro calibration are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lichtman, J. W., & Conchello, J.-A. (2005) · Nature Methods · doi:10.1038/nmeth817 · Cited by 1,742
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Apoptosis induced in Jurkat cells by several agents is preceded by intracellular acidification.
Gottlieb, R. A., Nordberg, J., Skowronski, E., & Babior, B. M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.2.654 · Cited by 494
Spectral and photophysical studies of benzo[c]xanthene dyes: Dual emission pH sensors
Whitaker, J. E., Haugland, R. P., & Prendergast, F. G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90237-n · Cited by 397
Clerc, S., & Barenholz, Y. (1995) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(95)00214-6 · Cited by 145
Metadata
- Authors
- Bassnett, S., Reinisch, L., & Beebe, D. C.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 1990-01-01
- Volume
- 258
- Issue
- 1
- Pages
- C171-C178
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W2267384929
- Cited by
- 159
- References
- 0
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracellular pH measurement using single excitation-dual emission fluorescence ratios. https://app.cochat.ai/papers/10.1152/ajpcell.1990.258.1.c171
- The paper
- Bassnett, S., Reinisch, L., & Beebe, D. C. (1990). Intracellular pH measurement using single excitation-dual emission fluorescence ratios. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1990.258.1.c171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.