The DOI matches its Crossref record.
Shear stress inhibits adhesion of cultured mouse endothelial cells to lymphocytes by downregulating VCAM-1 expression
Abstract
Monolayers of endothelial cells (EC) cultured from mouse lymph nodes were exposed to controlled levels of shear stress (0-7.1 dyn/cm2) in a parallel plate flow chamber, and binding between the flow-loaded EC and mouse lymph node-derived lymphocytes was assayed. A large number of lymphocytes adhered to the stationary control EC, but in EC exposed to a shear stress of 1.5 dyn/cm2 for 6 h, the adhesion decreased to 68.8 +/- 12.8% (SD; n = 19) of control (n = 29, P < 0.001). The decrease in adhesion induced by flow loading was time and shear stress dependent and reversible. Treatment of stationary EC with a monoclonal antibody (MAb) to vascular cell adhesion molecule-1 (VCAM-1) reduced the adhesion to 70.6 +/- 11.5% (n = 19) of control (P < 0.001), whereas MAb to CD44 and to intercellular adhesion molecule-1 had no effect on it. Flow cytometric analysis revealed that the amount of VCAM-1 expressed on the cell surface was decreased to 48.5 +/- 15.8% (n = 6) of control by flow loading (P < 0.001). Flow loading experiments using two perfusates with different viscosities demonstrated that the decrease in VCAM-1 expression due to flow was shear stress rather than shear rate dependent. The detection of mRNA by reverse transcriptase-polymerase chain reaction showed that VCAM-1 mRNA levels were markedly depressed in EC exposed to flow loading.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650
Laminar Shear Stress: Mechanisms by Which Endothelial Cells Transduce an Atheroprotective Force
Traub, O., & Berk, B. C. (1998) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.18.5.677 · Cited by 1,085
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Iiyama, K., Hajra, L., Iiyama, M., Li, H., DiChiara, M., Medoff, B. D., & Cybulsky, M. I. (1999) · Circulation Research · doi:10.1161/01.res.85.2.199 · Cited by 632
Fluid shear stress and the vascular endothelium: for better and for worse
Resnick, N., Yahav, H., Shay-Salit, A., Shushy, M., Schubert, S., Zilberman, L. C. M., & Wofovitz, E. (2003) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(02)00052-4 · Cited by 577
Metadata
- Authors
- Ando, J., Tsuboi, H., Korenaga, R., Takada, Y., Toyama-Sorimachi, N., Miyasaka, M., & Kamiya, A.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 1994-09-01
- Volume
- 267
- Issue
- 3
- Pages
- C679-C687
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W1839057479
- Cited by
- 199
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shear stress inhibits adhesion of cultured mouse endothelial cells to lymphocytes by downregulating VCAM-1 expression. https://app.cochat.ai/papers/10.1152/ajpcell.1994.267.3.c679
- The paper
- Ando, J., Tsuboi, H., Korenaga, R., Takada, Y., Toyama-Sorimachi, N., Miyasaka, M., & Kamiya, A. (1994). Shear stress inhibits adhesion of cultured mouse endothelial cells to lymphocytes by downregulating VCAM-1 expression. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1994.267.3.c679
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.