Dynamic micromechanical properties of cultured rat atrial myocytes measured by atomic force microscopy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The atomic force microscope (AFM) was used to quantify micromechanical properties (i.e., localized to an area of approximately 0.015 microns 2) of cultured rat atrial myocytes. Quiescent cells in calcium-free solution were quite compressible over the nuclear region, e.g., a force of 3-4 nN produced 180-225 nm cell indentation. Transverse stiffness of quiescent cells increased by approximately 2-fold after an increase in extracellular calcium from 0 to 5 mM and by approximately 16-fold after fixation with Formalin. There was five- to eightfold variation in stiffness of quiescent cells over the cell surface, such that stiffness was lowest over the nuclear region, and it increased toward the cell periphery. These regional variations correlated with the cytoskeletal heterogeneity as revealed by the AFM and fluorescence imaging. Localized contractile activity of beating cells could be monitored in terms of the surface deformation with high transverse spatial (approximately 1-3 nm) and temporal (60-100 microseconds) resolutions. Alterations in cell contractile activity with physiological perturbations and dynamic changes in cell stiffness during a single contraction could be observed. These results demonstrate the feasibility of AFM-based characterization of highly localized cellular micromechanical properties. Relationships among localized cell mechanical behavior and the underlying biochemical and/or structural environment, a crucial aspect in understanding cellular (dys)function, can now be directly examined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Mathematical model for the effects of adhesion and mechanics on cell migration speed
DiMilla, P. A., Barbee, K., & Lauffenburger, D. A. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82027-6 · Cited by 613
Barbee, K. A., Davies, P. F., & Lal, R. (1994) · Circulation Research · doi:10.1161/01.res.74.1.163 · Cited by 350
Self-citationMechanical properties of isolated cardiac myocytes
Brady, A. J. (1991) · Physiological Reviews · doi:10.1152/physrev.1991.71.2.413 · Cited by 172
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Scaling the Microrheology of Living Cells
Fabry, B., Maksym, G. N., Butler, J. P., Glogauer, M., Navajas, D., & Fredberg, J. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.148102 · Cited by 1,261
Atomic force microscopy probing of cell elasticity
Kuznetsova, T. G., Starodubtseva, M. N., Yegorenkov, N. I., Chizhik, S. A., & Zhdanov, R. I. (2007) · Micron · doi:10.1016/j.micron.2007.06.011 · Cited by 794
Microrheology of Human Lung Epithelial Cells Measured by Atomic Force Microscopy
Alcaraz, J., Buscemi, L., Grabulosa, M., Trepat, X., Fabry, B., Farré, R., & Navajas, D. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75014-0 · Cited by 740
Mathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589
Metadata
- Authors
- Shroff, S. G., Saner, D. R., & Lal, R.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 1995-07-01
- Volume
- 269
- Issue
- 1
- Pages
- C286-C292
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W2461980944
- Cited by
- 260
- References
- 4
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.