The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An equibiaxial strain system for cultured cells
Abstract
We developed a device that applies homogeneous equibiaxial strains of 0-10% to a cell culture substrate and quantitatively verified transmission of substrate deformation to cultured cardiac cells. Clamped elastic membranes in both single-well and multiwell versions of the device are uniformly stretched by indentation with a plastic ring, resulting in strain that is directly proportional to the pitch-to-radius ratio. Two-dimensional deformations were measured by tracking fluorescent microspheres attached to the substrate and to cultured adult rat cardiac fibroblasts. For nominal stretches up to 18%, strains along circumferential and radial axes were equal in magnitude and homogeneously distributed with negligible shear. For 5% stretch, circumferential and radial strains in the substrate were 0.046 +/- 0.005 and 0.048 +/- 0.004 [not significant (NS)], respectively, and shear strain was 0.001 +/- 0.003 (NS). Calibration of both single-well and multiwell versions permits strain selection by device rotation. The reproducible application and quantification of homogeneous equibiaxial strain in cultured cells provides a quantitative approach for correlating mechanical stimuli to cellular transduction mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Cardiac Fibroblast: The Renaissance Cell
Souders, C. A., Bowers, S. L. K., & Baudino, T. A. (2009) · Circulation Research · doi:10.1161/circresaha.109.209809 · Cited by 984
Knöll, R., Hoshijima, M., Hoffman, H. M., Person, V., Lorenzen-Schmidt, I., Bang, M.-L., Hayashi, T., Shiga, N., Yasukawa, H., Schaper, W., et al. (2002) · Cell · doi:10.1016/s0092-8674(02)01226-6 · Cited by 786
Self-citationTechniques for mechanical stimulation of cells in vitro: a review
Brown, T. D. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00177-3 · Cited by 539
Leri, A., Claudio, P. P., Li, Q., Wang, X., Reiss, K., Wang, S., Malhotra, A., Kajstura, J., & Anversa, P. (1998) · Journal of Clinical Investigation · doi:10.1172/jci316 · Cited by 456
Cardiac fibroblasts: friend or foe?
Baudino, T. A., Carver, W., Giles, W., & Borg, T. K. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00023.2006 · Cited by 427
Metadata
- Authors
- Lee, A. A., Delhaas, T., Waldman, L. K., MacKenna, D. A., Villarreal, F. J., & McCulloch, A. D.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 1996-10-01
- Volume
- 271
- Issue
- 4
- Pages
- C1400-C1408
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W2255633033
- Cited by
- 164
- References
- 1
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An equibiaxial strain system for cultured cells. https://app.cochat.ai/papers/10.1152/ajpcell.1996.271.4.c1400
- The paper
- Lee, A. A., Delhaas, T., Waldman, L. K., MacKenna, D. A., Villarreal, F. J., & McCulloch, A. D. (1996). An equibiaxial strain system for cultured cells. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1996.271.4.c1400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.