In vitro system to study realistic pulsatile flow and stretch signaling in cultured vascular cells
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We developed a novel real-time servo-controlled perfusion system that exposes endothelial cells grown in nondistensible or distensible tubes to realistic pulse pressures and phasic shears at physiological mean pressures. A rate-controlled flow pump and linear servo-motor are controlled by digital proportional-integral-derivative feedback that employs previously digitized aortic pressure waves as a command signal. The resulting pressure mirrors the recorded waveform and can be digitally modified to yield any desired mean and pulse pressure amplitude, typically 0–150 mmHg at shears of 0.5–15 dyn/cm 2. The system accurately reproduces the desired arterial pressure waveform and cogenerates physiological flow and shears by the interaction of pressure with the tubing impedance. Rectangular glass capillary tubes [1-mm inside diameter (ID)] are used for real-time fluorescent imaging studies (i.e., pH i, NO, Ca 2+), whereas silicon distensible tubes (4-mm ID) are used for more chronic (i.e., 2–24 h) studies regarding signal transduction and gene expression. The latter have an elastic modulus of 12.4 · 10 6 dyn/cm 2 similar to in vivo vessels of this size and are studied with the use of a benchtop system. The new approach provides the first in vitro application of realistic mechanical pulsatile forces on vascular cells and should facilitate studies of phasic shear and distension interaction and pulsatile signal transduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Self-citationMalek, A. M., & Izumo, S. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.713 · Cited by 531
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Ventricular Arterial Stiffening: Integrating the Pathophysiology
Kass, D. A. (2005) · Hypertension · doi:10.1161/01.hyp.0000168053.34306.d4 · Cited by 335
Self-citationSoucy, K. G., Ryoo, S., Benjo, A., Lim, H. K., Gupta, G., Sohi, J. S., Elser, J., Aon, M. A., Nyhan, D., Shoukas, A. A., et al. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00138.2006 · Cited by 135
Ramamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
Wang, X.-Y., Pei, Y., Xie, M., Jin, Z.-H., Xiao, Y.-S., Wang, Y., Zhang, L.-N., Li, Y., & Huang, W.-H. (2015) · Lab on a Chip · doi:10.1039/c4lc00973h · Cited by 77
Metadata
- Authors
- Peng, X., Recchia, F. A., Byrne, B. J., Wittstein, I. S., Ziegelstein, R. C., & Kass, D. A.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 2000-09-01
- Volume
- 279
- Issue
- 3
- Pages
- C797-C805
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W2185483792
- Cited by
- 80
- References
- 2
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro system to study realistic pulsatile flow and stretch signaling in cultured vascular cells. https://app.cochat.ai/papers/10.1152/ajpcell.2000.279.3.c797
- The paper
- Peng, X., Recchia, F. A., Byrne, B. J., Wittstein, I. S., Ziegelstein, R. C., & Kass, D. A. (2000). In vitro system to study realistic pulsatile flow and stretch signaling in cultured vascular cells. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.2000.279.3.c797
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.