Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A highly sensitive and specific assay for determination of IGF-I bioactivity in human serum

Chen, Jian-Wen, Ledet, Thomas, Ørskov, Hans, Jessen, Niels, Lund, Sten, Whittaker, Jonathan, De Meyts, Pierre, Larsen, Maj Britt, Christiansen, Jens Sandahl, Frystyk, Jan · 2003 · American Journal of Physiology-Endocrinology and Metabolism

Abstract

At present, the circulating bioactivity of insulin-like growth factor I (IGF-I) is estimated by immunological measurements of IGF-I levels. However, immunoassays ignore the modifying effects of the IGF-binding proteins (IGFBPs) on the interaction between IGF-I and the IGF-I receptor (IGF-IR). Therefore, we developed an IGF-I kinase receptor activation assay (KIRA) based on cells transfected with the human IGF-IR gene. The bioassay was sensitive (detection limit 0.08 μg/l), specific (cross-reactivity of insulin, insulin analogs, and proinsulin was <1%; IGF-II cross-reactivity was 12%), and accurate (within- and between-assay coefficients of variation <7 and <15%). The operational range of the assay (0.25–10.0 μg/l) allowed for determination of IGF-I bioactivity in serum from patients with, for example, growth hormone deficiency, type 1 diabetes, and acromegaly. Addition of IGFBPs dose dependently reduced the KIRA signal, whereas addition of IGF-II to preformed complexes (1:1 molar ratio) of IGF-I and IGFBP dose dependently increased IGF-I bioactivity by displacement of bound IGF-I. In conclusion, the KIRA will enable us to compare IGF-I bioactivity with existing immunological measurements of IGF-I in serum and, hopefully, to elucidate the factors that determine IGF-I bioactivity in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpendo.00410.2002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 178

Metadata

Authors
Chen, J.-W., Ledet, T., Ørskov, H., Jessen, N., Lund, S., Whittaker, J., De Meyts, P., Larsen, M. B., Christiansen, J. S., & Frystyk, J.
Venue
American Journal of Physiology-Endocrinology and Metabolism
Published
2003-06-01
Volume
284
Issue
6
Pages
E1149-E1155
ISSN
  • 0193-1849 (ISSN-L)
  • 1522-1555
OpenAlex
W2168923938
Cited by
178
References
1
FWCI
4.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A highly sensitive and specific assay for determination of IGF-I bioactivity in human serum. https://app.cochat.ai/papers/10.1152/ajpendo.00410.2002
The paper
Chen, J.-W., Ledet, T., Ørskov, H., Jessen, N., Lund, S., Whittaker, J., De Meyts, P., Larsen, M. B., Christiansen, J. S., & Frystyk, J. (2003). A highly sensitive and specific assay for determination of IGF-I bioactivity in human serum. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.00410.2002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.