Impact of continuous and pulsatile insulin delivery on net hepatic glucose uptake
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The pancreas releases insulin in a pulsatile manner; however, studies assessing the liver’s response to insulin have used constant infusion rates. Our aims were to determine whether the secretion pattern of insulin [continuous (CON) vs. pulsatile] in the presence of hyperglycemia 1) influences net hepatic glucose uptake (NHGU) and 2) entrains NHGU. Chronically catheterized conscious dogs fasted for 42 h received infusions including peripheral somatostatin, portal insulin (0.25 mU·kg−1·min−1), peripheral glucagon (0.9 ng·kg−1·min−1), and peripheral glucose at a rate double the glucose load to the liver. After the basal period, insulin was infused for 210 min at either four times the basal rate (1 mU·kg−1·min−1) or an identical amount in pulses of 1 and 4 min duration, followed by intervals of 11 and 8 min (CON, 1/11, and 4/8, respectively) in which insulin was not infused. A variable peripheral glucose infusion containing [3 H]glucose clamped glucose levels at twice the basal level (∼200 mg/dl) throughout each study. Hepatic metabolism was assessed by combining tracer and arteriovenous difference techniques. Arterial plasma insulin (μU/ml) either increased from basal levels of 6 ± 1 to a constant level of 22 ± 4 in CON or oscillated from 5 ± 1 to 416 ± 79 and from 6 ± 1 to 123 ± 43 in 1/11 and 4/8, respectively. NHGU (−0.8 ± 0.3, 0.4 ± 0.2, and −0.9 ± 0.4 mg·kg−1·min−1) and net hepatic fractional extraction of glucose (0.04 ± 0.01, 0.04 ± 0.01, and 0.05 ± 0.01 mg·kg−1·min−1) were similar during the experimental period. Spectral analysis was performed to assess whether a correlation existed between the insulin secretion pattern and NHGU. NHGU was not augmented by pulsatile insulin delivery, and there is no evidence of entrainment in hepatic glucose metabolism. Thus the loss of insulin pulsatility per se likely has little or no impact on the effectiveness of insulin in regulating liver glucose uptake.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sindelar, D. K., Balcom, J. H., Chu, C. A., Neal, D. W., & Cherrington, A. D. (1996) · Diabetes · doi:10.2337/diab.45.11.1594 · Cited by 134 · cited 2×
“This observation is consistent with previous studies in which plasma glucose concentrations 190 mg/dl in the presence of elevated insulin levels (4 basal) were shown to effectively suppress glucose production by the liver (23, 26).”
BackgroundResultSelf-citation
Cited by
Motivations and Methods for Analyzing Pulsatile Hormone Secretion
Veldhuis, J. D., Keenan, D. M., & Pincus, S. M. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0005 · Cited by 223
Pulsatile Portal Vein Insulin Delivery Enhances Hepatic Insulin Action and Signaling
Matveyenko, A. V., Liuwantara, D., Gurlo, T., Kirakossian, D., Dalla Man, C., Cobelli, C., White, M. F., Copps, K. D., Volpi, E., Fujita, S., et al. (2012) · Diabetes · doi:10.2337/db11-1462 · Cited by 163
Closing in on the mechanisms of pulsatile insulin secretion
Bertram, R., Satin, L. S., & Sherman, A. S. (2018) · Diabetes · doi:10.2337/dbi17-0004 · Cited by 83
Matveyenko, A. V., Veldhuis, J. D., & Butler, P. C. (2008) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.90451.2008 · Cited by 54
Metadata
- Authors
- Grubert, J. M., Lautz, M., Lacy, D. B., Moore, M. C., Farmer, B., Penaloza, A., Cherrington, A. D., & McGuinness, O. P.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 2005-08
- Volume
- 289
- Issue
- 2
- Pages
- E232-E240
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2030876003
- Cited by
- 24
- References
- 1
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.