A microdialysis method allowing characterization of intercellular water space in humans
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To evaluate the usefulness of the tissue-microdialysis technique in humans, the glucose concentration in the intercellular water space was measured in the abdominal subcutaneous region in healthy subjects. A 30 X 0.3 mm dialysis fiber with a 3,000 MW cutoff was used. The dialysis catheter was calibrated in vivo by perfusing it with isotonic saline and four to five different glucose concentrations (0-5 mM). The perfusate was collected in 6-min fractions. Regression analysis of the results of the calibration yielded the perfusate glucose concentration, which was in equilibrium with the surrounding tissue. Validation experiments showed that this value could be precisely measured and represented the intercellular glucose concentration. The recovery of glucose in the dialysate (dialysate glucose concentration/medium) during the calibrations in vivo was only approximately one-half of that in vitro (recovery factors 0.28 vs. 0.44, respectively). Under steady-state conditions, the intercellular glucose concentration was similar to the glucose levels in the cubital vein. It is concluded that this microdialysis technique is a useful tool allowing measurements of metabolically active substances in the intercellular water space in vivo provided that the calibrations are properly performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ungerstedt, U., Herrera-Marschitz, M., Jungnelius, U., Stahle, L., Tossman, U., & Zetterström, T. (1982) · Advances in Dopamine Research · doi:10.1016/b978-0-08-027391-4.50025-3 · Cited by 210
Shichiri, M., Kawamori, R., Hakui, N., Yamasaki, Y., & Abe, H. (1984) · Diabetes · doi:10.2337/diab.33.12.1200 · Cited by 85
Cited by
Lipolysis and lipid mobilization in human adipose tissue
Lafontan, M., & Langin, D. (2009) · Progress in Lipid Research · doi:10.1016/j.plipres.2009.05.001 · Cited by 826
Microdialysis—principles and applications for studies in animals and man
UNGERSTEDT, U. (1991) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1991.tb00459.x · Cited by 812
Microdialysis—Theory and application
Benveniste, H., & Hüttemeier, P. C. (1990) · Progress in Neurobiology · doi:10.1016/0301-0082(90)90027-e · Cited by 646
Sullivan, M. R., Danai, L. V., Lewis, C. A., Chan, S. H., Gui, D. Y., Kunchok, T., Dennstedt, E. A., Vander Heiden, M. G., & Muir, A. (2019) · eLife · doi:10.7554/elife.44235 · Cited by 588
“Indeed, the IF glucose concentration in healthy skin is very similar to that of circulating plasma (Lonnroth et al., 1987).”
BackgroundBenveniste, H. (1989) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1989.tb07243.x · Cited by 523
Metadata
- Authors
- Lonnroth, P., Jansson, P. A., & Smith, U.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1987-08-01
- Volume
- 253
- Issue
- 2
- Pages
- E228-E231
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2187766168
- Cited by
- 633
- References
- 2
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.