The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Microdialysis—principles and applications for studies in animals and man
Abstract
Abstract.Microdialysis is a technique for sampling the chemistry of the individual tissues and organs of the body, and is applicable to both animal and human studies. The basic principle is to mimic the function of a capillary blood vessel by perfusing a thin dialysis tube implanted into the tissue with a physiological liquid. The perfusate is analysed chemically and reflects the composition of the extracellular fluid with time due to the diffusion of substances back and forth over the membrane. Microdialysis is thus a technique whereby substances may be both recovered from and supplied to a tissue. The most important features of microdialysis are as follows: it samples the extracellular fluid, which is the origin of all blood chemistry; it samples continuously for hours or days without withdrawing blood; and it purifies the sample and simplifies chemical analysis by excluding large molecules from the perfusate. However, the latter feature renders the technique unsuitable for sampling large molecules such as proteins. The technique has been extensively used in the neurosciences to monitor neurotransmitter release, and is now finding application in monitoring of the chemistry of peripheral tissues in both animal and human studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hernandez, L., & Hoebel, B. G. (1988) · Life Sciences · doi:10.1016/0024-3205(88)90036-7 · Cited by 627
In situ studies of catecholamine-induced lipolysis in human adipose tissue using microdialysis.
Arner, P., Kriegholm, E., & Engfeldt, P. (1990) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)12597-4 · Cited by 68
Cited by
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Hillered, L., Vespa, P. M., & Hovda, D. A. (2005) · Journal of Neurotrauma · doi:10.1089/neu.2005.22.3 · Cited by 365
Helmy, A., Carpenter, K. L., Menon, D. K., Pickard, J. D., & Hutchinson, P. J. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.142 · Cited by 337
Effects of cortisol on lipolysis and regional interstitial glycerol levels in humans
Djurhuus, C. B., Gravholt, C. H., Nielsen, S., Mengel, A., Christiansen, J. S., Schmitz, O. E., & Møller, N. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00544.2001 · Cited by 219
Metadata
- Authors
- UNGERSTEDT, U.
- Venue
- Journal of Internal Medicine
- Publisher
- Wiley
- Published
- 1991-10
- Volume
- 230
- Issue
- 4
- Pages
- 365-373
- ISSN
- 0954-6820 (ISSN-L)
- 1365-2796
- OpenAlex
- W2144499458
- Cited by
- 812
- References
- 2
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microdialysis—principles and applications for studies in animals and man. https://app.cochat.ai/papers/10.1111/j.1365-2796.1991.tb00459.x
- The paper
- UNGERSTEDT, U. (1991). Microdialysis—principles and applications for studies in animals and man. Journal of Internal Medicine. https://doi.org/10.1111/j.1365-2796.1991.tb00459.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.