Precision and accuracy of doubly labeled water energy expenditure by multipoint and two-point methods
The DOI matches its Crossref record.
Abstract
Two-point or multipoint, that is the question. Equations are developed to compare the precision and accuracy of energy expenditure, as estimated from doubly labeled water data, when analyzed by the multipoint and two-point methods. The equations convert the enrichments of deuterium and oxygen-18 into their ratio and product, quantities that are less covariant than the two isotopes themselves are. This is important not only for estimating the precision but also as a graphical aid, since the ratios of the enrichments model carbon dioxide production, whereas the enrichment products largely model water turnover. Using data on 12 human subjects from the United Kingdom and The Gambia as examples, the combined precision and accuracy of the multipoint method (CV 3.6%) was found to be appreciably better than the two-point method (CV 5.4%). The bias in the multipoint estimate of body pool size would need to be three times as large as was observed before it canceled out the better precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Subar, A. F. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg092 · Cited by 1,070
Neuhouser, M. L., Tinker, L., Shaw, P. A., Schoeller, D., Bingham, S. A., Horn, L. V., Beresford, S. A. A., Caan, B., Thomson, C., Satterfield, S., et al. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwn026 · Cited by 354
Corder, K., van Sluijs, E. M., Wright, A., Whincup, P., Wareham, N. J., & Ekelund, U. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.26739 · Cited by 253
Doubly labelled water assessment of energy expenditure: principle, practice, and promise.
Westerterp, K. R. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3641-x · Cited by 219
“Initially, it was preferred to calculate isotope elimination from serial samples, collected on a daily basis, the multipoint method (Cole and Coward 1992).”
MethodBrage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“Average internal error of uncorrected CO2 production measurements was 5%, as described in detail elsewhere [36,37].”
BackgroundMethod
Metadata
- Authors
- Cole, T. J., & Coward, W. A.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1992-11-01
- Volume
- 263
- Issue
- 5
- Pages
- E965-E973
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W1855619563
- Cited by
- 98
- References
- 0
- FWCI
- 0.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precision and accuracy of doubly labeled water energy expenditure by multipoint and two-point methods. https://app.cochat.ai/papers/10.1152/ajpendo.1992.263.5.e965
- The paper
- Cole, T. J., & Coward, W. A. (1992). Precision and accuracy of doubly labeled water energy expenditure by multipoint and two-point methods. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1992.263.5.e965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.