Estimation of Free-Living Energy Expenditure by Heart Rate and Movement Sensing: A Doubly-Labelled Water Study
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurate assessment of energy expenditure (EE) is important for the study of energy balance and metabolic disorders. Combined heart rate (HR) and acceleration (ACC) sensing may increase precision of physical activity EE (PAEE) which is the most variable component of total EE (TEE). OBJECTIVE: To evaluate estimates of EE using ACC and HR data with or without individual calibration against doubly-labelled water (DLW) estimates of EE. DESIGN: 23 women and 23 men (22-55 yrs, 48-104 kg, 8-46%body fat) underwent 45-min resting EE (REE) measurement and completed a 20-min treadmill test, an 8-min step test, and a 3-min walk test for individual calibration. ACC and HR were monitored and TEE measured over 14 days using DLW. Diet-induced thermogenesis (DIT) was calculated from food-frequency questionnaire. PAEE (TEE ÷ REE ÷ DIT) and TEE were compared to estimates from ACC and HR using bias, root mean square error (RMSE), and correlation statistics. RESULTS: Mean(SD) measured PAEE and TEE were 66(25) kJ·day(-1)·kg(-1), and 12(2.6) MJ·day(-1), respectively. Estimated PAEE from ACC was 54(15) kJ·day(-1)·kg(-1) (p<0.001), with RMSE 24 kJ·day(-1)·kg(-1) and correlation r = 0.52. PAEE estimated from HR and ACC+HR with treadmill calibration were 67(42) and 69(25) kJ·day(-1)·kg(-1) (bias non-significant), with RMSE 34 and 20 kJ·day(-1)·kg(-1) and correlations r = 0.58 and r = 0.67, respectively. Similar results were obtained with step-calibrated and walk-calibrated models, whereas non-calibrated models were less precise (RMSE: 37 and 24 kJ·day(-1)·kg(-1), r = 0.40 and r = 0.55). TEE models also had high validity, with biases <5%, and correlations r = 0.71 (ACC), r = 0.66-0.76 (HR), and r = 0.76-0.83 (ACC+HR). CONCLUSIONS: Both accelerometry and heart rate may be used to estimate EE in adult European men and women, with improved precision if combined and if heart rate is individually calibrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These research devices (BodyMedia Core and Actiheart™) have been extensively validated and shown to accurately predict energy expenditure [11,20–28].”
From Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors (2017) · cites this paper as [24]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This method has been validated against gold-standard measures of energy expenditure in laboratory and free-living conditions [22–24].”
From Resting heart rate is a population-level biomarker of cardiorespiratory fitness: The Fenland Study (2023) · cites this paper as [24]
In the citing paper
“Individual calibration has been shown to improve energy expenditure prediction in free-living [24,26,27] and laboratory settings [23,25].”
From Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors (2017) · cites this paper as [24]
In the citing paper
“The Actiheart™ has previously been validated against doubly labelled water [24,26,27] and has been used as a criterion measure of free-living energy expenditure in epidemiology studies [35].”
From Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors (2017) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 1×
“5 minutes or less if 90% of age-predicted maximal HR [25] was reached.”
BackgroundPredicting basal metabolic rate, new standards and review of previous work.
Wn, S. (1985) · PubMed · Cited by 2,958
Basal metabolic rate studies in humans: measurement and development of new equations
Henry, C. (2005) · Public Health Nutrition · doi:10.1079/phn2005801 · Cited by 1,033 · cited 12×
“Sensitivity analyses were conducted disregarding measured RMR in all calculations (estimation and criterion), and instead using predicted RMR calculated with both the Oxford equations [46] and the Schofield equations [48].”
MethodInfluentialThe sources of external work in level walking and running.
Cavagna, G. A., Thys, H., & Zamboni, A. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011613 · Cited by 804
Energy expenditure by doubly labeled water: validation in humans and proposed calculation
Schoeller, D. A., Ravussin, E., Schutz, Y., Acheson, K. J., Baertschi, P., & Jequier, E. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.5.r823 · Cited by 684
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Self-citationTate, D. F., Jackvony, E. H., & Wing, R. R. (2003) · JAMA · doi:10.1001/jama.289.14.1833 · Cited by 666
Research works printed but not linked: 1
- Brage S, Westgate K, Wijndaele K, Godinho J, Griffin S, Wareham N. Evaluation of a method for minimising diurnal information bias in objective sensor data. ICAMPAM (Amherst) Conference Proceeding 2013.
Cited by
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625
Wearable-device-measured physical activity and future health risk
Strain, T., Wijndaele, K., Dempsey, P. C., Sharp, S. J., Pearce, M., Jeon, J., Lindsay, T., Wareham, N., & Brage, S. (2020) · Nature Medicine · doi:10.1038/s41591-020-1012-3 · Cited by 355
Self-citationPhilip, A., & Kumar, A. R. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214424 · Cited by 281
Chowdhury, E. A., Richardson, J. D., Holman, G. D., Tsintzas, K., Thompson, D., & Betts, J. A. (2016) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.122044 · Cited by 255
White, T., Westgate, K., Wareham, N. J., & Brage, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0167472 · Cited by 169
Self-citation
Metadata
- Authors
- Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J.
- Affiliations
- University of Cambridge (GB)
- Lund University (SE)
- European Bioinformatics Institute (GB)
- MRC Elsie Widdowson Laboratory (GB)
- Corresponding author
- Brage, Søren
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-09-08
- Volume
- 10
- Issue
- 9
- Pages
- e0137206
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4562631
- OpenAlex
- W2171723694
- Semantic Scholar
- 9cfd7980e2973ab827b8941c570e13417e259926
- Cited by
- 151
- References
- 75
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 9 · 2023: 7 · 2022: 12 · 2021: 18 · 2020: 13 · 2019: 26 · 2018: 21 · 2017: 18 · 2016: 10
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- BIBSYS Brage (BIBSYS (Norway)) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Lund University Publications (Lund University) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- Wellcome Trust
- National Institute for Health and Care Research (NF-SI-0512-10135)
- Medical Research Council (MC_UU_12015, MC_UU_12015/3, MC_UU_12015/1)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
- Keywords
- free-living energy expenditure, heart rate monitoring, accelerometry, doubly labeled water, physical activity energy expenditure, total energy expenditure, individual calibration, step test, walk test, diet-induced thermogenesis, energy balance, measurement validity, women and men comparison, body fat percentage
- MeSH terms
- Adult, Energy Metabolism, Fats, Female, Heart Rate, Humans, Male, Monitoring, Physiologic, Motor Activity, Rest, Urine, Water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of Free-Living Energy Expenditure by Heart Rate and Movement Sensing: A Doubly-Labelled Water Study. https://app.cochat.ai/papers/10.1371/journal.pone.0137206
- The paper
- Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015). Estimation of Free-Living Energy Expenditure by Heart Rate and Movement Sensing: A Doubly-Labelled Water Study. PLOS ONE. https://doi.org/10.1371/journal.pone.0137206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.