CoChat

Whole body protein kinetics using Phe and Tyr tracers: an evaluation of the accuracy of approximated flux values

Short, Kevin R., Meek, Shon E., Moller, Niels, Ekberg, Karin, Nair, K. Sreekumaran · 1999 · American Journal of Physiology-Endocrinology and Metabolism
Cited by 39

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Phenylalanine (Phe) kinetics are increasingly used in studies of amino acid kinetics, because the metabolic fate of Phe is limited to incorporation into protein (protein synthesis, S p) and catabolism via hydroxylation ( Q pt) to tyrosine (Tyr). Besides an infusion of labeled Phe to measure Phe flux ( Q p), a priming dose of Tyr and an independent Tyr tracer are used to measure Tyr flux ( Q t) and Q pt. Alternatively, Q t, Q pt, and S p can be approximated by using equations, based on Phe and Tyr concentrations in body proteins, that eliminate the need for a Tyr tracer. To evaluate the accuracy of this approach, data were obtained from 12 type I diabetic patients and 24 nondiabetic control subjects who were studied with the full complement of tracers both with and without insulin infusion. S p approximations closely matched measured values in both groups (mean difference <2%, all values <5%), but the agreement was poor for Q pt (error range = −8 to +43%) and Q t (error range −22 to +41%). Insulin status had no effect on these comparisons. The lower approximation error for S p vs. Q pt is due to the small contribution (∼10%) of Q pt to Q p. Approximation error for Q pt( r > 0.99) can be explained by variability in the ratio of Tyr to Phe coming from protein breakdown, ( Q t − Q pt)/ Q p. Ideally, all fluxes should be directly measured, but these data suggest that whole body S p can be approximated with an acceptably small margin of error. However, the same equations do not yield reliably accurate values for Q pt or Q t.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpendo.1999.276.6.e1194

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 39

Metadata

Authors
Short, K. R., Meek, S. E., Moller, N., Ekberg, K., & Nair, K. S.
Venue
American Journal of Physiology-Endocrinology and Metabolism
Published
1999-06-01
Volume
276
Issue
6
Pages
E1194-E1200
ISSN
  • 0193-1849 (ISSN-L)
  • 1522-1555
OpenAlex
W2114437130
Cited by
39
References
3
FWCI
0.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Whole body protein kinetics using Phe and Tyr tracers: an evaluation of the accuracy of approximated flux values. https://app.cochat.ai/papers/10.1152/ajpendo.1999.276.6.e1194
The paper
Short, K. R., Meek, S. E., Moller, N., Ekberg, K., & Nair, K. S. (1999). Whole body protein kinetics using Phe and Tyr tracers: an evaluation of the accuracy of approximated flux values. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1999.276.6.e1194

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.