The DOI matches its Crossref record.
Measurement of interstitial albumin in human skeletal muscle and adipose tissue by open-flow microperfusion
Abstract
The absolute concentration of albumin was measured in the interstitial fluid of subcutaneous adipose tissue and skeletal muscle in six healthy volunteers by combining the method of open-flow microperfusion and the no-net-flux calibration technique. By use of open-flow microperfusion, four macroscopically perforated double lumen catheters were inserted into the tissue regions of interest and constantly perfused. Across the macroscopic perforations of the catheters interstitial fluid was partially recovered in the perfusion fluid. Catheters were perfused with five solutions, each containing different concentrations of albumin. Absolute interstitial albumin concentrations were calculated by applying linear regression analysis to perfusate vs. sampled albumin concentration (no-net-flux calibration technique). Interstitial albumin concentrations were significantly lower ( P < 0.0001) in adipose tissue (7.36 g/l; r = 0.99, P < 0.0003; range: 4.3–10.7 g/l) and in skeletal muscle (13.25 g/l; r = 0.99, P < 0.0012; range: 9.7 to 15.7 g/l) compared with the serum concentration (48.9 ± 0.7 g/l, mean ± SE, n = 6; range: 46.4–50.4 g/l). Furthermore, interstitial albumin concentrations were significantly higher in skeletal muscle compared with adipose tissue ( P < 0.01). The study indicates that open-flow microperfusion allows stable sampling of macromolecules from the interstitial space of peripheral tissue compartments. Moreover, the present data report for the first time in healthy humans in vivo the true albumin concentrations of interstitial fluid of adipose tissue and skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Mechanism of Protraction of Insulin Detemir, a Long-Acting, Acylated Analog of Human Insulin
Havelund, S., Plum, A., Ribel, U., Jonassen, I., Vølund, A., Markussen, J., & Kurtzhals, P. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000036926.54824.37 · Cited by 429
Albumin and Mammalian cell culture: implications for biotechnology applications
Francis, G. L. (2010) · Cytotechnology · doi:10.1007/s10616-010-9263-3 · Cited by 376
A Novel Strategy for Physiologically Based Predictions of Human Pharmacokinetics
Jones, H. M., Parrott, N., Jorga, K., & Lav??, T. (2006) · Clinical Pharmacokinetics · doi:10.2165/00003088-200645050-00006 · Cited by 352
Rabbani, G., Lee, E. J., Ahmad, K., Baig, M. H., & Choi, I. (2018) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.7b00976 · Cited by 271
De Buck, S. S., Sinha, V. K., Fenu, L. A., Nijsen, M. J., Mackie, C. E., & Gilissen, R. A. H. J. (2007) · Drug Metabolism and Disposition · doi:10.1124/dmd.107.015644 · Cited by 256
Metadata
- Authors
- Ellmerer, M., Schaupp, L., Brunner, G. A., Sendlhofer, G., Wutte, A., Wach, P., & Pieber, T. R.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 2000-02-01
- Volume
- 278
- Issue
- 2
- Pages
- E352-E356
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2183315284
- Cited by
- 170
- References
- 0
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of interstitial albumin in human skeletal muscle and adipose tissue by open-flow microperfusion. https://app.cochat.ai/papers/10.1152/ajpendo.2000.278.2.e352
- The paper
- Ellmerer, M., Schaupp, L., Brunner, G. A., Sendlhofer, G., Wutte, A., Wach, P., & Pieber, T. R. (2000). Measurement of interstitial albumin in human skeletal muscle and adipose tissue by open-flow microperfusion. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.2000.278.2.e352
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.