The DOI matches its Crossref record.
Validation of tonometric measurement of gut intramural pH during endotoxemia and mesenteric occlusion in pigs
Abstract
Tonometry is a minimally invasive method for estimating gastrointestinal intramural pH (pHi). Tissue pH is calculated by using the Henderson-Hasselbalch equation and measurements of arterial [HCO-3] and CO2 tension (PCO3) of saline contained in a Silastic balloon within the lumen of the gut. The validity of the method rests on two key assumptions: 1) PCO2 in saline in the tonometer balloon is similar to tissue PCO2 and 2) tissue and arterial [HCO-3] are similar. To validate this method, ileal pHi measured directly with a microelectrode was compared with pHi estimated tonometrically in four groups of anesthetized pigs. Group I (n = 4) were controls. In group II (n = 4), intestinal tissue acidosis was induced by total occlusion of the superior mesenteric artery (SMA). In group III (n = 5), acidosis was induced by partial occlusion of the SMA. In group IV (n = 4), tissue acidosis was induced by endotoxemia. Agreement was excellent between direct and tonometric measurements in groups I and IV and less good in groups II and III. Weighted mean correlation coefficients (rw) for the two measurement methods were 0.743 and 0.9447 in groups II and IV, respectively. Correlation coefficients for the individual animals in group III were more variable than the other groups and ranged from 0.547 to 0.990. The tonometric method for measuring GI pHi is invalid under conditions of zero flow and leads to error under conditions of low flow. However, the method is reliable in the setting of tissue acidosis induced by endotoxemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of Stored-Blood Transfusion on Oxygen Delivery in Patients With Sepsis
Marik, P. E. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500230106037 · Cited by 812
Assessment of Splanchnic Oxygenation by Gastric Tonometry in Patients With Acute Circulatory Failure
Maynard, N. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510100053032 · Cited by 446
Marik, P. E. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03520170064037 · Cited by 401
Mythen, M. G., & Webb, A. R. (1994) · Intensive Care Medicine · doi:10.1007/bf01707662 · Cited by 361
Marik, P. E. (1993) · Chest · doi:10.1378/chest.104.1.225 · Cited by 311
Metadata
- Authors
- Antonsson, J. B., Boyle, C. C., Kruithoff, K. L., Wang, H. L., Sacristan, E., Rothschild, H. R., & Fink, M. P.
- Venue
- American Journal of Physiology-Gastrointestinal and Liver Physiology
- Publisher
- American Physiological Society
- Published
- 1990-10-01
- Volume
- 259
- Issue
- 4
- Pages
- G519-G523
- ISSN
- 0193-1857 (ISSN-L)
- 1522-1547
- OpenAlex
- W2124865771
- Cited by
- 195
- References
- 0
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of tonometric measurement of gut intramural pH during endotoxemia and mesenteric occlusion in pigs. https://app.cochat.ai/papers/10.1152/ajpgi.1990.259.4.g519
- The paper
- Antonsson, J. B., Boyle, C. C., Kruithoff, K. L., Wang, H. L., Sacristan, E., Rothschild, H. R., & Fink, M. P. (1990). Validation of tonometric measurement of gut intramural pH during endotoxemia and mesenteric occlusion in pigs. American Journal of Physiology-Gastrointestinal and Liver Physiology. https://doi.org/10.1152/ajpgi.1990.259.4.g519
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.