Detection of gastric slow wave propagation from the cutaneous electrogastrogram
Open accessThe DOI matches its Crossref record.
Abstract
The gastric slow wave is originated in the proximal stomach and propagates distally toward the pylorus. It determines the maximum frequency and propagation of gastric contractions. The aim of this study was to detect the propagation of the gastric slow wave from the surface electrogastrogram (EGG). The study was performed in 11 healthy subjects of normal weight. Gastric myoelectrical activity was recorded for 1 h in the fasting state with the use of a specially designed multichannel recording device that was composed of four identical amplifiers with cutoff frequencies of 1.8 and 16.0 cycles/min. Four active electrodes were placed on the abdomen along the gastric axis and were connected to a common reference electrode placed near the xiphoid process, yielding four-channel bipolar EGG signals. Cross-covariance analysis was performed to compute the time lag among the four channels. There was a time lag in EGG waveform between channels 1 and 4 (9.6 ± 1.1 s); the average time during which the time lag was observed (≥3 s) was 89.9 ± 9.0%. There was a significant difference in the time lag among different adjacent channels ( P< 0.04); the time lag observed between channels 3 and 4 was significantly smaller than that between channels 1 and 2( P < 0.03). No correlation was found between the body mass index and the time lag between channels 1 and 4 ( r= −0.31, P = 0.3). It was concluded that, with a multichannel recording device with identical multiamplifiers and an appropriate arrangement of abdominal electrodes, the propagation of the gastric slow wave could be identified from the EGG in healthy subjects. This method may be used to detect the coupling of the gastric slow wave noninvasively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parkman, H. P., Hasler, W. L., Barnett, J. L., & Eaker, E. Y. (2003) · Neurogastroenterology & Motility · doi:10.1046/j.1365-2982.2003.00396.x · Cited by 336
Electrogastrography: Methodology, Validation and Applications
Yin, J., & Chen, J. D. Z. (2013) · Journal of Neurogastroenterology and Motility · doi:10.5056/jnm.2013.19.1.5 · Cited by 265
Self-citationRichter, C. G., Babo-Rebelo, M., Schwartz, D., & Tallon-Baudry, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.043 · Cited by 151
Wolpert, N., Rebollo, I., & Tallon‐Baudry, C. (2020) · Psychophysiology · doi:10.1111/psyp.13599 · Cited by 96
The vagus nerve mediates the stomach-brain coherence in rats
Cao, J., Wang, X., Chen, J., Zhang, N., & Liu, Z. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119628 · Cited by 25
Self-citationTodd, J., Cardellicchio, P., Swami, V., Cardini, F., & Aspell, J. E. (2021) · Cortex · doi:10.1016/j.cortex.2021.07.006 · Cited by 24
Metadata
- Authors
- Chen, J. D. Z., Zou, X., Lin, X., Ouyang, S., & Liang, J.
- Venue
- American Journal of Physiology-Gastrointestinal and Liver Physiology
- Publisher
- American Physiological Society
- Published
- 1999-08-01
- Volume
- 277
- Issue
- 2
- Pages
- G424-G430
- ISSN
- 0193-1857 (ISSN-L)
- 1522-1547
- OpenAlex
- W2166071054
- Cited by
- 98
- References
- 0
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.