No-reflow phenomenon in the heart and brain

Kloner, Robert A., King, Kevin S., Harrington, Michael G. · 2018 · American Journal of Physiology-Heart and Circulatory Physiology

Abstract

The no-reflow phenomenon refers to the observation that when an organ is made ischemic by occlusion of a large artery supplying it, restoration of patency in that artery does not restore perfusion to the microvasculature supplying the parenchyma of that organ. This has been observed after prolonged arterial occlusions in the heart (30–90 min), brain, skin, and kidney. In experimental models, zones of no reflow in the heart are characterized by ultrastructural microvascular damage, including focal endothelial swelling obstructing the lumen of small vessels. Blood elements such as neutrophil plugs, platelets, and stacking of erythrocytes have also been implicated. No reflow is associated with poor healing of the myocardial infarction. In patients, no reflow is associated with a poor clinical outcome independent of infarct size, suggesting that therapy for no reflow may be an important approach to improving outcome for ST elevation myocardial infarction. No reflow occurs after reperfusion of experimental cerebral ischemia and may be observed after only 5-min episodes of ischemia. Aggregation of blood elements may play a greater role than in cardiac no reflow. No reflow in the brain may involve cortical spreading depression with disturbed local vascular control and high, vasculotonic levels of extracellular K+ concentration, postischemic swelling in endothelial cells and abutting end feet of pericytes, pericyte contraction and death, interstitial edema with collapse of cerebral capillaries, and inflammatory reaction. New guidelines suggesting that reperfusion for stroke may be considered as late as 24 h after the onset of symptoms suggest that clinicians may be seeing more no reflow in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00183.2018

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 230

Metadata

Authors
Kloner, R. A., King, K. S., & Harrington, M. G.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2018-09-01
Volume
315
Issue
3
Pages
H550-H562
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2805953136
Cited by
230
References
9
FWCI
9.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: No-reflow phenomenon in the heart and brain. https://app.cochat.ai/papers/10.1152/ajpheart.00183.2018
The paper
Kloner, R. A., King, K. S., & Harrington, M. G. (2018). No-reflow phenomenon in the heart and brain. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00183.2018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.