The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Substrate size as a determinant of fibrillatory activity maintenance in a mathematical model of canine atrium
Abstract
Tissue size has been considered an important determinant of atrial fibrillation (AF), but recent work has questioned the critical size hypothesis. Here, we use a previously developed mathematical model of the two-dimensional canine atrium with realistic action potential, ionic, and conduction properties to address substrate size effects on the maintenance of fibrillatory activity. Cholinergic AF was simulated at different acetylcholine (ACh) concentrations ([ACh]) and distributions, with substrate area varied 11.1-fold. Automated phase singularity detection was used to facilitate the analysis of arrhythmic activity. The duration of activity induced by a single extrastimulus increased with increasing substrate dimensions. Two general mechanisms underlying activity were observed and were differentially affected by substrate size. For large mean [ACh], single primary rotors anchored in low-[ACh] zones maintained activity and substrate dimensions were not critical. At lower mean [ACh], extensive spiral wave meander prevented the emergence of single stable rotors. Prolonged activity was favored when substrate size permitted a sufficiently large number of simultaneous longer-lasting rotors that extinction of all was unlikely. Thus either single dominant rotor or multiple reentrant spiral generator mechanisms could maintain fibrillatory activity in this model and were differentially dependent on substrate size. These results speak to recent debates about the role in AF of single driver rotors versus multiple reentrant circuit mechanisms by suggesting that either may maintain fibrillatory atrial activity depending on atrial size and electrophysiological properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relation between echocardiographically determined left atrial size and atrial fibrillation.
Henry, W. L., Morganroth, J., Pearlman, A. S., Clark, C. E., Redwood, D. R., Itscoitz, S. B., & Epstein, S. E. (1976) · Circulation · doi:10.1161/01.cir.53.2.273 · Cited by 641
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Andrade, J., Khairy, P., Dobrev, D., & Nattel, S. (2014) · Circulation Research · doi:10.1161/circresaha.114.303211 · Cited by 1,187
Self-citationAtrial Remodeling and Atrial Fibrillation: Mechanisms and Implications
Nattel, S., Burstein, B., & Dobrev, D. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.107.754564 · Cited by 1,124
Self-citationAtrial Remodeling and Atrial Fibrillation
Nattel, S., & Harada, M. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.555 · Cited by 736
Self-citationNew antiarrhythmic drugs for treatment of atrial fibrillation
Dobrev, D., & Nattel, S. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60096-7 · Cited by 284
Self-citation
Metadata
- Authors
- Zou, R., Kneller, J., Leon, L. J., & Nattel, S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-09
- Volume
- 289
- Issue
- 3
- Pages
- H1002-H1012
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2171404421
- Cited by
- 113
- References
- 1
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.