The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Quantification of right ventricular afterload in patients with and without pulmonary hypertension
Abstract
Right ventricular (RV) afterload is commonly defined as pulmonary vascular resistance, but this does not reflect the afterload to pulsatile flow. The purpose of this study was to quantify RV afterload more completely in patients with and without pulmonary hypertension (PH) using a three-element windkessel model. The model consists of peripheral resistance ( R), pulmonary arterial compliance ( C), and characteristic impedance ( Z). Using pulmonary artery pressure from right-heart catheterization and pulmonary artery flow from MRI velocity quantification, we estimated the windkessel parameters in patients with chronic thromboembolic PH (CTEPH; n = 10) and idiopathic pulmonary arterial hypertension (IPAH; n = 9). Patients suspected of PH but in whom PH was not found served as controls (NONPH; n = 10). R and Z were significantly lower and C significantly higher in the NONPH group than in both the CTEPH and IPAH groups ( P < 0.001). R and Z were significantly lower in the CTEPH group than in the IPAH group ( P < 0.05). The parameters R and C of all patients obeyed the relationship C = 0.75/ R ( R 2 = 0.77), equivalent to a similar RC time in all patients. Mean pulmonary artery pressure P and C fitted well to C = 69.7/P (i.e., similar pressure dependence in all patients). Our results show that differences in RV afterload among groups with different forms of PH can be quantified with a windkessel model. Furthermore, the data suggest that the RC time and the elastic properties of the large pulmonary arteries remain unchanged in PH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Primary Pulmonary Hypertension
Rubin, L. J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199701093360207 · Cited by 1,726
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Chronic thromboembolic pulmonary hypertension
Kim, N. H., Delcroix, M., Jais, X., Madani, M. M., Matsubara, H., Mayer, E., Ogo, T., Tapson, V. F., Ghofrani, H.-A., & Jenkins, D. P. (2019) · European Respiratory Journal · doi:10.1183/13993003.01915-2018 · Cited by 1,007
Diagnosis and differential assessment of pulmonary arterial hypertension
Barst, R. J., McGoon, M., Torbicki, A., Sitbon, O., Krowka, M. J., Olschewski, H., & Gaine, S. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.02.032 · Cited by 992
Noninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique.
Kitabatake, A., Inoue, M., Asao, M., Masuyama, T., Tanouchi, J., Morita, T., Mishima, M., Uematsu, M., Shimazu, T., Hori, M., et al. (1983) · Circulation · doi:10.1161/01.cir.68.2.302 · Cited by 779
Mechanical properties of arteries
Dobrin, P. B. (1978) · Physiological Reviews · doi:10.1152/physrev.1978.58.2.397 · Cited by 746
An artificial arterial system for pumping hearts.
Westerhof, N., Elzinga, G., & Sipkema, P. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.5.776 · Cited by 556
Self-citationLangewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
Chronic thromboembolic pulmonary hypertension
Dartevelle, P., Fadel, E., Mussot, S., Chapelier, A., Hervé, P., de Perrot, M., Cerrina, J., Ladurie, F. L., Lehouerou, D., Humbert, M., et al. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00079704 · Cited by 447
Mahapatra, S., Nishimura, R. A., Sorajja, P., Cha, S., & McGoon, M. D. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.054 · Cited by 416
Estimation of total arterial compliance: an improved method and evaluation of current methods
Liu, Z., Brin, K. P., & Yin, F. C. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.3.h588 · Cited by 378
Evaluation of methods for estimation of total arterial compliance
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.4.h1540 · Cited by 267
Self-citationPulmonary Arterial Pulse Wave Velocity and Impedance in Man
Milnor, W. R., Conti, C. R., Lewis, K. B., & O'Rourke, M. F. (1969) · Circulation Research · doi:10.1161/01.res.25.6.637 · Cited by 238
Hydraulic Power Associated with Pulmonary Blood Flow and its Relation to Heart Rate
MILNOR, W. R., BERGEL, D. H., & BARGAINER, J. D. (1966) · Circulation Research · doi:10.1161/01.res.19.3.467 · Cited by 197
Compliance of the Human Pulmonary Arterial System in Disease
Reuben, S. R. (1971) · Circulation Research · doi:10.1161/01.res.29.1.40 · Cited by 191
Choosing among generalized linear models applied to medical data
Lindsey, J. K., & Jones, B. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980115)17:1<59::aid-sim733>3.0.co;2-7 · Cited by 178
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368245 · Cited by 173
Self-citationA nonlinear model of the arterial system incorporating a pressure-dependent compliance
Li, J. K., Cui, T., & Drzewiecki, G. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55678 · Cited by 103
Correction of phase offset errors in main pulmonary artery flow quantification
Lankhaar, J., Hofman, M. B. M., Marcus, J. T., Zwanenburg, J. J. M., Faes, T. J. C., & Noordegraaf, A. V. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20361 · Cited by 101
Self-citationPulmonary arterial compliance in dogs and pigs: the three-element windkessel model revisited
Segers, P., Brimioulle, S., Stergiopulos, N., Westerhof, N., Naeije, R., Maggiorini, M., & Verdonck, P. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h725 · Cited by 90
Self-citationMuthurangu, V., Atkinson, D., Maxime Sermesant, B., Miquel, M. E., Hegde, S. R., Johnson, R. I., Andriantsimiavona, R., Taylor, A. M., Baker, E. J., Tulloh, R. M. R., et al. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00957.2004 · Cited by 85
Sniderman, A. D., & FITCHETT, D. H. (1988) · International Journal of Cardiology · doi:10.1016/0167-5273(88)90261-6 · Cited by 71
MRI evaluation of right ventricular pressure overload in chronic obstructive pulmonary disease
Marcus, J. T., Noordegraaf, A. V., VRIES, P. M. J. M. D., van Rossum, A. C., Roseboom, B., Heethaar, R. M., & Postmus, P. E. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080502 · Cited by 53
Self-citationIdentification of the three-element windkessel model incorporating a pressure-dependent compliance
Cappello, A., Gnudi, G., & Lamberti, C. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02368323 · Cited by 43
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Self-citationvan de Veerdonk, M. C., Kind, T., Marcus, J. T., Mauritz, G.-J., Heymans, M. W., Bogaard, H.-J., Boonstra, A., Marques, K. M. J., Westerhof, N., & Vonk-Noordegraaf, A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.068 · Cited by 846
Self-citation
Metadata
- Authors
- Lankhaar, J.-W., Westerhof, N., Faes, T. J. C., Marques, K. M. J., Marcus, J. T., Postmus, P. E., & Vonk-Noordegraaf, A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2006-10
- Volume
- 291
- Issue
- 4
- Pages
- H1731-H1737
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2168807618
- Cited by
- 338
- References
- 26
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.