The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Biaxial mechanical properties of intact and layer-dissected human carotid arteries at physiological and supraphysiological loadings
Abstract
Specimens of intact wall tubes of human common carotid arteries (CCA), internal carotid arteries (ICA) ( n = 11, age 77.6 yr, SD 6.3), and related adventitia and media-intima tubes are mechanically examined. Cyclic, quasi-static extension-inflation tests at different axial stretches are performed on preconditioned tube specimens. Stress-free configurations show significant stress releases in the circumferential direction of the intact CCA and ICA walls and in the axial directions of the intact CCA walls and the CCA and ICA adventitias. All investigated tissues exhibit strong nonlinear, pseudoelastic mechanical behavior with small hysteresis. The “inversion” feature, where the pressure/axial stretch relationship becomes a vertical line, is found only for intact walls. Axial “inversion stretches” are 1.15 (SD 0.06) for CCA and 1.14 (SD 0.06) for ICA, and related external axial forces are 0.43 N (SD 0.15) and 0.30 N (SD 0.22), respectively. Significant negative correlations between age and axial inversion stretches for CCA ( r = −0.67, P = 0.03) and ICA ( r = −0.29, P = 0.04) are identified. Adventitias are very compliant at low pressures, but change into stiff tubes at high pressures. The burst pressure of the adventitia is beyond 250 kPa. A relatively low burst pressure of ∼60 kPa is found in the media-intima tubes, in which the pressure/circumferential stretch relationships are almost independent of the axial stretches. Stress analyses indicate a high degree of material anisotropy for all investigated tissues. High circumferential and axial stresses occur in the media-intima tubes at physiological conditions. The obtained data are intended to serve for an improvement of constitutive laws, determination of constitutive parameters, and enhancing our knowledge of the mechanical functions of arteries and their associated layers in specific pathophysiological and clinical problems, such as hypertension and angioplasty with stenting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Cited by
Endothelial fluid shear stress sensing in vascular health and disease
Baeyens, N., Bandyopadhyay, C., Coon, B. G., Yun, S., & Schwartz, M. A. (2016) · Journal of Clinical Investigation · doi:10.1172/jci83083 · Cited by 575
Constitutive modelling of arteries
Holzapfel, G. A., & Ogden, R. W. (2010) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2010.0058 · Cited by 528
Self-citationBiomechanical properties and microstructure of human ventricular myocardium
Sommer, G., Schriefl, A. J., Andrä, M., Sacherer, M., Viertler, C., Wolinski, H., & Holzapfel, G. A. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.06.031 · Cited by 290
Self-citationKhamdaeng, T., Luo, J., Vappou, J., Terdtoon, P., & Konofagou, E. E. (2012) · Ultrasonics · doi:10.1016/j.ultras.2011.09.006 · Cited by 156
Metadata
- Authors
- Sommer, G., Regitnig, P., Költringer, L., & Holzapfel, G. A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2010-03
- Volume
- 298
- Issue
- 3
- Pages
- H898-H912
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2135933070
- Cited by
- 183
- References
- 1
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biaxial mechanical properties of intact and layer-dissected human carotid arteries at physiological and supraphysiological loadings. https://app.cochat.ai/papers/10.1152/ajpheart.00378.2009
- The paper
- Sommer, G., Regitnig, P., Költringer, L., & Holzapfel, G. A. (2010). Biaxial mechanical properties of intact and layer-dissected human carotid arteries at physiological and supraphysiological loadings. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00378.2009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.