CoChat

Effect of skin surface cooling on central venous pressure during orthostatic challenge

Cui, Jian, Durand, Sylvain, Levine, Benjamin D., Crandall, Craig G. · 2005 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 56

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Orthostatic stress leads to a reduction in central venous pressure (CVP), which is an index of cardiac preload. Skin surface cooling has been shown to improve orthostatic tolerance, although the mechanism resulting in this outcome is unclear. One possible mechanism may be that skin surface cooling attenuates the drop in CVP during an orthostatic challenge, thereby preserving cardiac filling. To test this hypothesis, CVP, arterial blood pressure, heart rate, and skin blood flow, as well as skin and sublingual temperatures, were recorded in nine healthy subjects during lower body negative pressure (LBNP) in both normothermic and skin surface cooling conditions. Cardiac output was also measured via acetylene rebreathing. Progressive LBNP was applied at −10, −15, −20, and −40 mmHg at 5 min/stage. Before LBNP, skin surface cooling lowered mean skin temperature, increased CVP, and increased mean arterial blood pressure (all P < 0.001) but did not change mean heart rate ( P = 0.38). Compared with normothermic conditions, arterial blood pressure remained elevated throughout progressive LBNP. Although progressive LBNP decreased CVP under both thermal conditions, during cooling CVP at each stage of LBNP was significantly greater relative to normothermia. Moreover, at higher levels of LBNP with skin cooling, stroke volume was significantly greater relative to normothermic conditions. These data indicate that skin surface cooling induced an upward shift in CVP throughout LBNP, which may be a key factor for preserving preload, stroke volume, and blood pressure and improving orthostatic tolerance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00383.2005

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 56

Metadata

Authors
Cui, J., Durand, S., Levine, B. D., & Crandall, C. G.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2005-12
Volume
289
Issue
6
Pages
H2429-H2433
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2137664885
Cited by
56
References
4
FWCI
2.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of skin surface cooling on central venous pressure during orthostatic challenge. https://app.cochat.ai/papers/10.1152/ajpheart.00383.2005
The paper
Cui, J., Durand, S., Levine, B. D., & Crandall, C. G. (2005). Effect of skin surface cooling on central venous pressure during orthostatic challenge. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00383.2005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.