CoChat

Gender affects calf venous compliance at rest and during baroreceptor unloading in humans

Monahan, Kevin D., Ray, Chester A. · 2004 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 73

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Leg venous compliance is a determinant of peripheral venous pooling during orthostatic stress such that high venous compliance could contribute to reduced orthostatic tolerance. We tested the hypotheses that 1) calf venous compliance is reduced during baroreceptor unloading, and 2) calf venous compliance is greater in women than men. Twelve men (27 ± 2 yr) and 12 women (25 ± 2 yr) were studied in the supine posture. Calf venous compliance was determined by inflating a thigh venous collecting cuff to 60 mmHg for 8 min and then decreasing cuff pressure at a rate of 1 mmHg/s to 0 mmHg. The slope of the pressure-compliance relation (compliance = β 1+ 2·β 2·cuff pressure), which is the first derivative of the quadratic pressure-volume relation [(Δlimb volume) = β 0+ β 1·(cuff pressure) + β 2·(cuff pressure)2] during the reduction in collecting cuff pressure, was used to assess venous compliance at baseline and during one-legged lower body negative pressure (LBNP; —50 mmHg). At baseline, calf venous compliance was 48% lower ( P < 0.001) in women than men and decreased in men (Δ—25 ± 8%; P < 0.05) but not women (Δ1 ± 11%) during LBNP. Rhythmic ischemic handgrip (Δ6 ± 9%) and cold pressor testing (Δ—9 ± 7%) did not alter calf venous compliance in a subgroup of men ( n = 6). These data indicate gender-dependent effects on calf venous compliance under conditions associated with low sympathetic outflow (i.e., rest) and high sympathetic outflow (i.e., LBNP). However, they cannot explain gender-associated differences in orthostatic tolerance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00719.2003

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 73

Metadata

Authors
Monahan, K. D., & Ray, C. A.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2004-03
Volume
286
Issue
3
Pages
H895-H901
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2168552977
Cited by
73
References
4
FWCI
3.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gender affects calf venous compliance at rest and during baroreceptor unloading in humans. https://app.cochat.ai/papers/10.1152/ajpheart.00719.2003
The paper
Monahan, K. D., & Ray, C. A. (2004). Gender affects calf venous compliance at rest and during baroreceptor unloading in humans. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00719.2003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.