Contribution of systemic vascular resistance and total arterial compliance to effective arterial elastance in humans
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The respective contribution of systemic vascular resistance ( R) and total arterial compliance ( C) to the arterial load remains to be established in humans. Effective arterial elastance ( E a), i.e., the left ventricular end-systolic pressure (LVESP)-over-stroke volume ratio, is a reliable estimate of arterial load. It is widely accepted that E a mainly relates to mean aortic pressure (MAP) and thus to the R-to- T ratio ( R/ T ratio), where T is cycle length. We tested the contribution of R/ T and 1/ C to E a in 20 normotensive and 46 hypertensive subjects (MAP range: 84–160 mmHg). The multilinear model applied ( E a = 1.00 R/ T + 0.42/ C – 0.04; r 2 = 0.97). The sensitivity of E a to a change in R/ T was 2.5 times higher than to a similar change in 1/ C in both normotensive and hypertensive adults. The LVESP was more strongly related to systolic aortic pressure (SAP; r 2 = 0.94) than to MAP ( r 2 = 0.83), and LVESP matched 90% SAP (bias = 0 ± 5mmHg). An alternative model of E a is proposed, in which E a is proportional to the heart rate × SAP product-over-cardiac index ratio whatever the MAP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological aspects of primary hypertension.
Folkow, B. (1982) · Physiological Reviews · doi:10.1152/physrev.1982.62.2.347 · Cited by 1,768
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330 · cited 2×
“Given that the subjects in the present study were free of aortic stenosis and hypertrophic cardiomyopathy, our finding is also in keeping with previous results showing that 1) peak LV pressure is usually achieved close to the volume point of minimal LV volume (11, 37); 2) peak LV pressure and LVESP are close in magnit…”
Gobel, F. L., Norstrom, L. A., Nelson, R. R., Jorgensen, C. R., & Wang, Y. (1978) · Circulation · doi:10.1161/01.cir.57.3.549 · Cited by 866
Pulse pressure—a review of mechanisms and clinical relevance
Dart, A. M., & Kingwell, B. A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01108-1 · Cited by 836 · cited 1×
“The SV-to-PP ratio was calculated as an estimate of C (5, 10, 13), and its reciprocal, i.”
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Briand, M., Dumesnil, J. G., Kadem, L., Tongue, A. G., Rieu, R., Garcia, D., & Pibarot, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.081 · Cited by 493
Chantler, P. D., Lakatta, E. G., & Najjar, S. S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90600.2008 · Cited by 360
Ventricular–Vascular Interaction in Heart Failure
Borlaug, B. A., & Kass, D. A. (2008) · Heart Failure Clinics · doi:10.1016/j.hfc.2007.10.001 · Cited by 315
Ventricular–Vascular Interaction in Heart Failure
Borlaug, B. A., & Kass, D. A. (2011) · Cardiology Clinics · doi:10.1016/j.ccl.2011.06.004 · Cited by 225
Metadata
- Authors
- Chemla, D., Antony, I., Lecarpentier, Y., & Nitenberg, A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2003-08
- Volume
- 285
- Issue
- 2
- Pages
- H614-H620
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2324396556
- Cited by
- 148
- References
- 4
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.