CoChat

The nonpeptide angiotensin-(1–7) receptor Mas agonist AVE-0991 attenuates heart failure induced by myocardial infarction

Ferreira, Anderson J., Jacoby, Bruno A., Araújo, Cícero A. A., Macedo, Filipe A. F. F., Silva, Gerluza A. B., Almeida, Alvair P., Caliari, Marcelo V., Santos, Robson A. S. · 2007 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 126

The DOI matches its Crossref record.

Abstract

The nonpeptide AVE-0991, which has been reported as a selective ligand for the angiotensin-(1–7) [ANG-(1–7)] receptor Mas, has actions similar to those attributed to the cardioprotective product of the renin-angiotensin system, ANG-(1–7). In this study, we evaluated the cardiac effects of AVE-0991 in normal and infarcted male Wistar rats. Myocardial infarction was induced by left coronary artery ligation. At the end of the treatment, the Langendorff technique was used to analyze cardiac function. Left ventricle serial sections were dyed with Gomori trichrome stain to quantify the infarcted area. In normal hearts, AVE-0991 produced a significant decrease in perfusion pressure and an increase in systolic tension, rate of tension rise and fall (±dT/d t), and heart rate. These effects were completely blocked by the perfusion of the hearts with a solution containing the selective ANG-(1–7) antagonist A-779. N G-nitro-l-arginine methyl ester treatment abolished the AVE-0991-induced vasodilation in isolated hearts. AVE-0991 significantly attenuated the decrease in systolic tension (sham operated, 13.00 ± 1.02 g; infarction, 7.18 ± 0.66 g; AVE treated, 9.23 ± 1.05 g, n = 5), +dT/d t, −dT/d t, and heart rate induced by myocardial infarction. Infarction-induced vasoconstriction was completely prevented by AVE-0991 treatment. Furthermore, AVE-0991 significantly decreased the infarcted area (6.98 ± 1.01 vs. 3.94 ± 1.04 mm 2 in AVE-treated rats). These data indicate that the compound AVE-0991 produces beneficial effects in isolated perfused rat hearts involving the ANG-(1–7) receptor Mas and the release of nitric oxide. In addition, our results indicate that AVE-0991 attenuates postischemic heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00828.2006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Ferreira, A. J., Jacoby, B. A., Araújo, C. A. A., Macedo, F. A. F. F., Silva, G. A. B., Almeida, A. P., Caliari, M. V., & Santos, R. A. S.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2007-02
Volume
292
Issue
2
Pages
H1113-H1119
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2131363342
Cited by
126
References
0
FWCI
4.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.