CoChat

Length-tension relationships of small arteries, veins, and lymphatics from the rat mesenteric microcirculation

Zhang, Rong-zhen, Gashev, Anatoliy A., Zawieja, David C., Davis, Michael J. · 2007 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 72

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The passive and active length-tension relationships of isolated rat mesenteric lymphatics (∼150 μm ID), and adjacent small arteries (∼240 μm) and veins (∼275 μm) were compared under isometric conditions using a wire myograph. About 60% of the lymphatic vessels developed spontaneous contractions in physiological saline solution at nominal preload. To maximally activate smooth muscle, 145 mM K++ 5 × 10−5 M norepinephrine was used for arteries, and 145 mM K++ 1 × 10−6 M substance P was used for lymphatics and veins. In response, arteries exhibited monotonic force development to a plateau level, whereas lymphatics and veins showed biphasic force development, consisting of a transient force peak followed by partial relaxation to a plateau over ∼5 min. The passive and the active length-tension curves were similar in shape among all three vessels. However, the maximal active tension of arteries (3.4 ± 0.42 mN/mm) was significantly greater than peak active tension (0.59 ± 0.04 mN/mm) or plateau tension (0.20 ± 0.04 mN/mm) in small veins and greater than peak active tension (0.34 ± 0.02 mN/mm) or plateau tension (0.21 ± 0.02 mN/mm) in lymphatics. Maximal active medial wall stress was similar between lymphatics and veins but was approximately fivefold higher in small arteries. For lymphatics, the pressure calculated from the optimal preload was significantly higher than that found previously in isobaric studies of isolated lymphatics, suggesting the capacity to operate at higher than normal pressures for increased responsiveness. Our results represent the first mechanical comparisons of arterial, venous, and lymphatic vessels in the same vasculature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.01000.2005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 72

Metadata

Authors
Zhang, R.-Z., Gashev, A. A., Zawieja, D. C., & Davis, M. J.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2007-04
Volume
292
Issue
4
Pages
H1943-H1952
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2168255549
Cited by
72
References
1
FWCI
2.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Length-tension relationships of small arteries, veins, and lymphatics from the rat mesenteric microcirculation. https://app.cochat.ai/papers/10.1152/ajpheart.01000.2005
The paper
Zhang, R.-Z., Gashev, A. A., Zawieja, D. C., & Davis, M. J. (2007). Length-tension relationships of small arteries, veins, and lymphatics from the rat mesenteric microcirculation. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.01000.2005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.