The DOI matches its Crossref record.
Temporal and spatial variations of cell-free layer width in arterioles
Abstract
Separation of red blood cells and plasma in microcirculatory vessels produces a cell-free layer at the wall. This layer may be an important determinant of blood viscosity and wall shear stress in arterioles, where most of the hydraulic pressure loss in the circulatory system occurs and flow regulatory mechanisms are prominent. With the use of a newly developed method, the width of the cell-free layer was rapidly and repeatedly determined in arterioles (10- to 50-μm inner diameter) in the rat cremaster muscle at normal arterial pressure. The temporal variation of the cell-free layer width was non-Gaussian, but calculated mean and median values differed by <0.2 μm. The correlation length of the temporal variations downstream (an indication of mixing) was ∼30 μm and was independent of pseudoshear rate (ratio of mean velocity to vessel diameter) and of vessel diameter. The cell-free layer width was significantly different on opposite sides of the vessel and inversely related. Increasing red blood cell aggregability reduced this inverse relation but had no effect on correlation length. In the diameter range studied, the mean width of the cell-free layer increased from 0.8 to 3.1 μm and temporal variations increased from 30% to 70% of the mean width. Increased aggregability did not alter either relationship. In summary, the cell-free layer width in arterioles is diameter dependent and shows substantial non-Gaussian temporal variations. The temporal variations increase as diameter increases and are inversely related on opposite sides of the vessel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Margination of micro- and nano-particles in blood flow and its effect on drug delivery
Müller, K., Fedosov, D. A., & Gompper, G. (2014) · Scientific Reports · doi:10.1038/srep04871 · Cited by 312
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Blood Flow and Cell-Free Layer in Microvessels
FEDOSOV, D. A., CASWELL, B., POPEL, A. S., & KARNIADAKIS, G. E. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00056.x · Cited by 277
Self-citationShaping nano-/micro-particles for enhanced vascular interaction in laminar flows
Lee, S.-Y., Ferrari, M., & Decuzzi, P. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/49/495101 · Cited by 257
Ta, H. T., Truong, N. P., Whittaker, A. K., Davis, T. P., & Peter, K. (2018) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1316262 · Cited by 105
Metadata
- Authors
- Kim, S., Kong, R. L., Popel, A. S., Intaglietta, M., & Johnson, P. C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2007-09
- Volume
- 293
- Issue
- 3
- Pages
- H1526-H1535
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2168827635
- Cited by
- 174
- References
- 0
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temporal and spatial variations of cell-free layer width in arterioles. https://app.cochat.ai/papers/10.1152/ajpheart.01090.2006
- The paper
- Kim, S., Kong, R. L., Popel, A. S., Intaglietta, M., & Johnson, P. C. (2007). Temporal and spatial variations of cell-free layer width in arterioles. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.01090.2006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.