Total heart volume variation throughout the cardiac cycle in humans
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Variations in total heart volume (atria plus ventricles) during a cardiac cycle affect efficiency of cardiac pumping. The goals of this study were to confirm the presence, extent, and contributors of total heart volume variation during the cardiac cycle in healthy volunteers with the use of MRI. Eight healthy volunteers were examined by MRI at rest. Changes in total cardiac volume throughout the cardiac cycle were calculated using the following methods: 1) planimetry derived from gradient-echo cine images and 2) flow-sensitive sequences to quantify flow in all vessels leading to and from the heart. The maximum total heart volume diminished during systole by 8.2 ± 0.8% (SEM, range 4.8–10.6%) measured by method 1 and 8.8 ± 1.0% (SEM, range 5.6–11.8%) by method 2 with good agreement between the methods [difference according to Bland-Altman analysis −0.6% ± 1.0% (SD), intraclass correlation coefficient = 0.999]. This decrease in volume is predominantly explained by variation at the midcardiac level at the widest diameter of the heart with a left-sided predominance. In the short axis of the heart, the change of slice volume was proportional to the end-diastolic slice volume. The present study has confirmed the presence of total heart volume variation that predominantly occurs in the region of atrioventricular plane movement and on the left side. The total heart volume variation may relate to the efficiency of energy use by the heart to minimize displacement of surrounding tissue while accounting for the energy required to draw blood into the atria during ventricular systole.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Carlsson, M., Ugander, M., Mosén, H., Buhre, T., & Arheden, H. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01148.2006 · Cited by 265
Self-citationCardiac Scan: A Non-contact and Continuous Heart-based User Authentication System
Lin, F., Song, C., Zhuang, Y., Xu, W., Li, C., & Ren, K. (2017) · Proceedings of the 23rd Annual International Conference on Mobile Computing and Networking · doi:10.1145/3117811.3117839 · Cited by 179
“) and 3D deformation of the heart [12].”
BackgroundConformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Metadata
- Authors
- Carlsson, M., Cain, P., Holmqvist, C., Stahlberg, F., Lundback, S., & Arheden, H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2004-07
- Volume
- 287
- Issue
- 1
- Pages
- H243-H250
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1965900141
- Cited by
- 137
- References
- 2
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.