The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Cardiac Scan: A Non-contact and Continuous Heart-based User Authentication System
Abstract
Continuous authentication is of great importance to maintain the security level of a system throughout the login session. The goal of this work is to investigate a trustworthy, continuous, and non-contact user authentication approach based on a heart-related biometric that works in a daily-life environment. To this end, we present a novel, continuous authentication system, namely Cardiac Scan, based on geometric and non-volitional features of the cardiac motion. Cardiac motion is an automatic heart deformation caused by self-excitement of the cardiac muscle, which is unique to each user and is difficult (if not impossible) to counterfeit. Cardiac Scan features intrinsic liveness detection, unobtrusiveness, cost-effectiveness, and high usability. We prototype a remote, high-resolution cardiac motion sensing system based on the smart DC-coupled continuous-wave radar. Fiducial-based invariant identity descriptors of cardiac motion are extracted after the radar signal demodulation. We conduct a pilot study with 78 subjects to evaluate Cardiac Scan in accuracy, authentication time, permanence, evaluation in complex conditions, and vulnerability. Specifically, Cardiac Scan achieves 98.61% balanced accuracy (BAC) and 4.42% equal error rate (EER) in a real-world setup. We demonstrate that Cardiac Scan is a robust and usable continuous authentication system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“, a Butterworth bandpass filter) and 2) adaptive noise canceling techniques [86] (e.”
MethodSmart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
Frank, M., Biedert, R., Ma, E., Martinovic, I., & Song, D. (2013) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2225048 · Cited by 844 · cited 1×
“Behavioral screentouch features have also been explored for continuous authentication (e.g., Frank et al. [24] and Chan et al. [13]).”
BackgroundEmotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
Cited by
A survey on privacy and security of Internet of Things
Ogonji, M. M., Okeyo, G., & Wafula, J. M. (2020) · Computer Science Review · doi:10.1016/j.cosrev.2020.100312 · Cited by 230
CardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49
Self-citation
Metadata
- Authors
- Lin, F., Song, C., Zhuang, Y., Xu, W., Li, C., & Ren, K.
- Venue
- Proceedings of the 23rd Annual International Conference on Mobile Computing and Networking
- Publisher
- ACM
- Published
- 2017-10-04
- Pages
- 315-328
- ISSN
- 1543-5679 (ISSN-L)
- OpenAlex
- W2762561030
- Cited by
- 179
- References
- 4
- FWCI
- 11.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac Scan: A Non-contact and Continuous Heart-based User Authentication System. https://app.cochat.ai/papers/10.1145/3117811.3117839
- The paper
- Lin, F., Song, C., Zhuang, Y., Xu, W., Li, C., & Ren, K. (2017). Cardiac Scan: A Non-contact and Continuous Heart-based User Authentication System. Proceedings of the 23rd Annual International Conference on Mobile Computing and Networking. https://doi.org/10.1145/3117811.3117839
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.