Lymphangion coordination minimally affects mean flow in lymphatic vessels
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The lymphatic system returns interstitial fluid to the central venous circulation, in part, by the cyclical contraction of a series of “lymphangion pumps” in a lymphatic vessel. The dynamics of individual lymphangions have been well characterized in vitro; their frequencies and strengths of contraction are sensitive to both preload and afterload. However, lymphangion interaction within a lymphatic vessel has been poorly characterized because it is difficult to experimentally alter properties of individual lymphangions and because the afterload of one lymphangion is coupled to the preload of another. To determine the effects of lymphangion interaction on lymph flow, we adapted an existing mathematical model of a lymphangion (characterizing lymphangion contractility, lymph viscosity, and inertia) to create a new lymphatic vessel model consisting of several lymphangions in series. The lymphatic vessel model was validated with focused experiments on bovine mesenteric lymphatic vessels in vitro. The model was then used to predict changes in lymph flow with different time delays between onset of contraction of adjacent lymphangions (coordinated case) and with different relative lymphangion contraction frequencies (noncoordinated case). Coordination of contraction had little impact on mean flow. Furthermore, orthograde and retrograde propagations of contractile waves had similar effects on flow. Model results explain why neither retrograde propagation of contractile waves nor the lack of electrical continuity between lymphangions adversely impacts flow. Because lymphangion coordination minimally affects mean flow in lymphatic vessels, lymphangions have flexibility to independently adapt to local conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Cited by
Lymphatic pumping: mechanics, mechanisms and malfunction
Scallan, J. P., Zawieja, S. D., Castorena‐Gonzalez, J. A., & Davis, M. J. (2016) · The Journal of Physiology · doi:10.1113/jp272088 · Cited by 424
“After lymphatic contractions are triggered by an AP in one of the LMCs, the AP propagates rapidly from cell to cell (at 8 mm s−1), and in either direction, over the length of the lymphangion (McHale & Meharg, 1992; Zawieja et al. 1993; Venugopal et al. 2007).”
BackgroundMoore, J. E., & Bertram, C. D. (2018) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122316-045259 · Cited by 340
Modelling the lymphatic system: challenges and opportunities
Margaris, K. N., & Black, R. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0751 · Cited by 229
Contractility Patterns of Human Leg Lymphatics in Various Stages of Obstructive Lymphedema
Olszewski, W. L. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1413.010 · Cited by 86
Lymphatic pump-conduit duality: contraction of postnodal lymphatic vessels inhibits passive flow
Quick, C. M., Ngo, B. L., Venugopal, A. M., & Stewart, R. H. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00322.2008 · Cited by 40
Self-citationAdaptation of mesenteric lymphatic vessels to prolonged changes in transmural pressure
Dongaonkar, R. M., Nguyen, T. L., Quick, C. M., Hardy, J., Laine, G. A., Wilson, E., & Stewart, R. H. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00677.2012 · Cited by 38
Self-citation
Metadata
- Authors
- Venugopal, A. M., Stewart, R. H., Laine, G. A., Dongaonkar, R. M., & Quick, C. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2007-08
- Volume
- 293
- Issue
- 2
- Pages
- H1183-H1189
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2172031535
- Cited by
- 56
- References
- 1
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.