Regional variation of series elasticity in canine arterial smooth muscles
The DOI matches its Crossref record.
Abstract
Segments of carotid, iliac, renal, mesenteric, coronary, and internal thoracic arteries were studied in vitro to correlate the mechanical properties of series (SE) and parallel (PE) elastic elements with connective tissue (CT) composition and with active responses to potassium activation. The PE properties were determined using pressure-diameter data with passive smooth muscle (SM). SE properties were determined from periodic incremental releases imposed during isometric responses to [K+]O at a diameter corresponding to Lmax, the optimum muscle length. Active stress responses and diameter responses were determined using pressure-diameter data for active and passive conditions. Collagen and elastin contents were determined for each sample. No correlation was found between CT content and PE or SE properties for the various sites. A close correlation was found to exist between SE and PE properties at each site, i.e., the sites with the stiffest PE also had the stiffest SE. SM, with stiffer SE, had a larger diameter response with the same active stress response and the same diameter response with a smaller active stress response, compared to SM with more compliant SE. This suggests that passive properties of SM can have a significant influence on the external manifestations of contractile element properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
Gasser, T. C., Ogden, R. W., & Holzapfel, G. A. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0073 · Cited by 2,411
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“3(a) shows exemplary experimental data indicating that pressure–diameter relationships of a central artery (thoracic aorta) are indeed similar in the relaxed and contracted states [28].”
BackgroundMethodRachev, A., & Hayashi, K. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.191 · Cited by 254
Bank, A. J., Wang, H., Holte, J. E., Mullen, K., Shammas, R., & Kubo, S. H. (1996) · Circulation · doi:10.1161/01.cir.94.12.3263 · Cited by 248
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Metadata
- Authors
- Cox, R. H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1978-05-01
- Volume
- 234
- Issue
- 5
- Pages
- H542-H551
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2399338128
- Cited by
- 89
- References
- 0
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regional variation of series elasticity in canine arterial smooth muscles. https://app.cochat.ai/papers/10.1152/ajpheart.1978.234.5.h542
- The paper
- Cox, R. H. (1978). Regional variation of series elasticity in canine arterial smooth muscles. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1978.234.5.h542
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.