Widespread distribution and rate differentiation of the atrial pacemaker complex
The DOI matches its Crossref record.
Abstract
In a study to examine the basis of rate-related changes in the electrocardiographic P wave we found a multicentric rather than unifocal origin of the atrial depolarization wave in dogs. Three to five pacemakers, or origin points, were distributed over a 30- to 40-mm area compared to the 11-mm size of the sinus node. Two or three of the sites could excite simultaneously, or one specific site would dominate excitation. Each separate origin point dominated excitation within a specific range of heart rates, and on reaching either the upper or lower limits of this range, a new focus abruptly dominated and initiated the atrial wave front. We have obtained evidence to suggest that these findings may be explained by a widely distributed atrial pacemaker complex. The spatial distribution of this system exceeded the dimensions of the canine sinus node by a factor of three to four times. The pacemaker centers, although distributed, were consistently located at specific positions along the superior vena caval-right atrial junction. Also, each separate pacemaker site appeared functionally differentiated to generate a specific range of heart rates. We propose that in addition to the sinus node there are other specialized atrial pacemaker centers, and that this specialization, including the differentiated response and coordination, is conferred by focal receptor characteristics and their inputs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Genesis and Regulation of the Heart Automaticity
Mangoni, M. E., & Nargeot, J. (2008) · Physiological Reviews · doi:10.1152/physrev.00018.2007 · Cited by 600
Demonstration of a widely distributed atrial pacemaker complex in the human heart.
Boineau, J. P., Canavan, T. E., Schuessler, R. B., Cain, M. E., Corr, P. B., & Cox, J. L. (1988) · Circulation · doi:10.1161/01.cir.77.6.1221 · Cited by 304
Self-citation
Metadata
- Authors
- Boineau, J. P., Schuessler, R. B., Hackel, D. B., Miller, C. B., Brockus, C. W., & Wylds, A. C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1980-09-01
- Volume
- 239
- Issue
- 3
- Pages
- H406-H415
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2263313366
- Cited by
- 92
- References
- 0
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Widespread distribution and rate differentiation of the atrial pacemaker complex. https://app.cochat.ai/papers/10.1152/ajpheart.1980.239.3.h406
- The paper
- Boineau, J. P., Schuessler, R. B., Hackel, D. B., Miller, C. B., Brockus, C. W., & Wylds, A. C. (1980). Widespread distribution and rate differentiation of the atrial pacemaker complex. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1980.239.3.h406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.