Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record.

Demonstration of a widely distributed atrial pacemaker complex in the human heart.

Open access
Boineau, J P, Canavan, T E, Schuessler, R B, Cain, M E, Corr, P B, Cox, J L·1988·Circulation

Abstract

Atrial depolarization was analyzed in 14 patients with the Wolff-Parkinson-White syndrome undergoing surgery to ablate accessory atrioventricular pathways associated with tachyarrhythmias. Bipolar potentials were recorded simultaneously from 156 atrial epicardial electrodes arranged in three templates to fit the anterior and posterior aspects of both atria. Spontaneous or sinus rhythms were recorded, as were atrial escape rhythms after overdrive pacing at rates of 150 and 200 beats/min. Atrial activation maps revealed different patterns of impulse initiation varying from typical unifocal sinus node impulse origin, unifocal extranodal impulse origin, and multicentric impulse origin from two to four widely distributed atrial pacemaker sites. In subjects demonstrating only unifocal impulse origin during control or sinus rhythm, other widely divergent pacemaker sites were recorded in other maps during subsequent rhythms. In addition to sites located at the upper superior vena cava-right atrium junction, pacemakers also dominated at sites anterior and inferior to the sinus node region during both control and escape depolarizations. Most of the subjects were found to have two or more pacemaker sites when maps of all control and postpacing conditions were analyzed. The right atrial pacemaker region encompassed a zone of 7.5 X 1.5 cm centered about the long axis of the sulcus terminalis posteriorly and the precaval band anteriorly. An unexpected finding was the participation of left atrial escape pacemakers. The functional behavior of both the control and escape pacemakers, as assessed by sinus node recovery time, was normal, indicating physiologic operation of the extranodal sites as part of an overall system of distributed pacemakers involved in the control of rate. Although functional assessment was limited in these initial patient studies, correspondence with similar observations in extensive previous canine studies supports the concept of a widely distributed atrial pacemaker complex in man.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.77.6.1221

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 304

Metadata

Authors
Boineau, J. P., Canavan, T. E., Schuessler, R. B., Cain, M. E., Corr, P. B., & Cox, J. L.
Venue
Circulation
Published
1988-06
Volume
77
Issue
6
Pages
1221-1237
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1974966930
Cited by
304
References
0
FWCI
1.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Demonstration of a widely distributed atrial pacemaker complex in the human heart. https://app.cochat.ai/papers/10.1161/01.cir.77.6.1221
The paper
Boineau, J. P., Canavan, T. E., Schuessler, R. B., Cain, M. E., Corr, P. B., & Cox, J. L. (1988). Demonstration of a widely distributed atrial pacemaker complex in the human heart. Circulation. https://doi.org/10.1161/01.cir.77.6.1221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.