Left ventricular interaction with arterial load studied in isolated canine ventricle
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We developed a framework of analysis to predict the stroke volume (SV) resulting from the complex mechanical interaction between the ventricle and its arterial system. In this analysis, we characterized both the left ventricle and the arterial system by their end systolic pressure (Ps)-SV relationships and predicted SV from the intersection of the two relationship lines. The final output of the analysis was a formula that gives the SV for a given preload as a function of the ventricular properties (Ees, V0, and ejection time) and the arterial impedance properties (modeled in terms of a 3-element Windkessel). To test the validity of this framework for analyzing the ventriculoarterial interaction, we first determined the ventricular properties under a specific set of control arterial impedance conditions. With the ventricular properties thus obtained, we used the analytical formula to predict SVs under various combinations of noncontrol arterial impedance conditions and four preloads. The predicted SVs were compared with those measured while actually imposing the identical set of arterial impedance conditions and preload in eight isolated canine ventricles. The predicted SV was highly correlated (P less than 0.0001) with the measured one in all ventricles. The average correlation coefficient was 0.985 +/- 0.004 (SE), the slope 1.00 +/- 0.04, and the gamma-axis intercept 1.0 +/- 0.2 ml, indicating the accuracy of the prediction. We conclude that the representations of ventricle and arterial system by their Ps-SV relationships are useful in understanding how these two systems determine SV when they are coupled and interact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., SAGAWA, K., & SHOUKAS, A. A. (1973) · Circulation Research · doi:10.1161/01.res.32.3.314 · Cited by 1,502
Self-citationSUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330 · cited 3×
“Thus Suga and co-workers (10,12) described the relation of the left ventricular endsystolic pressure (P,,) to stroke volume (SV) as”
BackgroundSelf-citationDetermination of Cardiac Output By Equating Venous Return Curves With Cardiac Response Curves
Guyton, A. C. (1955) · Physiological Reviews · doi:10.1152/physrev.1955.35.1.123 · Cited by 588
Sagawa, K. (1981) · Circulation · doi:10.1161/01.cir.63.6.1223 · Cited by 585
Self-citationAn artificial arterial system for pumping hearts.
Westerhof, N., Elzinga, G., & Sipkema, P. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.5.776 · Cited by 556
Suga, H., Kitabatake, A., & SAGAWA, K. (1979) · Circulation Research · doi:10.1161/01.res.44.2.238 · Cited by 164
Self-citationSunagawa, K., Maughan, W. L., Friesinger, G. C., Guzmán, P. A., Chang, M.-S., & SAGAWA, K. (1982) · Circulation Research · doi:10.1161/01.res.50.5.727 · Cited by 117
Self-citationImpedance loading servo pump system for excised canine ventricle
Sunagawa, K., Burkhoff, D., Lim, K. O., & SAGAWA, K. (1982) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1982.243.2.h346 · Cited by 85
Self-citationCombined effects of aortic and right atrial pressures on aortic flow
Herndon, C., & Sagawa, K. (1969) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1969.217.1.65 · Cited by 79
Self-citation
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Burkhoff, D., Mirsky, I., & Suga, H. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00138.2005 · Cited by 763
Self-citationLeft atrial function: physiology, assessment, and clinical implications
Blume, G. G., Mcleod, C. J., Barnes, M. E., Seward, J. B., Pellikka, P. A., Bastiansen, P. M., & Tsang, T. S. M. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq175 · Cited by 518
Briand, M., Dumesnil, J. G., Kadem, L., Tongue, A. G., Rieu, R., Garcia, D., & Pibarot, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.081 · Cited by 493
Kass, D. A., Maughan, W. L., Guo, Z. M., Kono, A., Sunagawa, K., & Sagawa, K. (1987) · Circulation · doi:10.1161/01.cir.76.6.1422 · Cited by 486
Self-citation
Metadata
- Authors
- Sunagawa, K., Maughan, W. L., Burkhoff, D., & Sagawa, K.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1983-11-01
- Volume
- 245
- Issue
- 5
- Pages
- H773-H780
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1792854258
- Cited by
- 817
- References
- 9
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.