Excess tachycardia: heart rate after antimuscarinic agents in conscious dogs
The DOI matches its Crossref record.
Abstract
In conscious dogs the heart rate after atropine is higher than after bilateral vagotomy; we have termed the additional heart rate with atropine "excess tachycardia" (ET). In six dogs the cervical vagosympathetic trunks were exteriorized in skin tubes, and arterial and venous catheters were chronically implanted. Atropine sulfate (0.1 mg/kg iv) injected during cold blockade of the vagi increased the heart rate by only 6 +/- 4 (SE) beats/min (NS) but rewarming the vagi in five of the six dogs after atropine resulted in an additional heart rate increase (ET) of 26 +/- 6 beats/min (P less than 0.005). The ET (41 +/- 11 beats/min) tended to be larger when the animals were pretreated with 1 mg/kg propranolol (P = 0.09). Similar results were obtained when atropine methylbromide, a charged derivative of atropine sulfate, or glycopyrrolate, a synthetic antimuscarinic agent, was substituted for atropine sulfate (ET: 51 +/- 6 and 51 +/- 16 beats/min, respectively). Raising the arterial blood pressure with phenylephrine increased the heart rate further; lowering the blood pressure with sodium nitroprusside attenuated or abolished the ET. Our results show that ET is produced by antimuscarinic agents in general and is not mediated by the beta-adrenergic system. Furthermore, ET is present only when the cervical vagi are intact, probably because ET is mediated by cholinergic vagal efferent fibers via a mechanism that has not yet been recognized in cardiac rate control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects.
Hayano, J., Sakakibara, Y., Yamada, A., Yamada, M., Mukai, S., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90445-q · Cited by 746
Penttilä, J., Helminen, A., Jartti, T., Kuusela, T., Huikuri, H. V., Tulppo, M. P., Coffeng, R., & Scheinin, H. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00337.x · Cited by 567
Muscarinic receptor antagonists for overactive bladder
Abrams, P., & Andersson, K. (2007) · BJU International · doi:10.1111/j.1464-410x.2007.07205.x · Cited by 405
Vasoactive intestinal peptide: cardiovascular effects
Henning, R. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00229-7 · Cited by 280
Evans, J. M., Ziegler, M. G., Patwardhan, A. R., Ott, J. B., Kim, C. S., Leonelli, F. M., & Knapp, C. F. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.6.2611 · Cited by 269
Metadata
- Authors
- Rigel, D. F., Lipson, D., & Katona, P. G.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1984-02-01
- Volume
- 246
- Issue
- 2
- Pages
- H168-H173
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2339543347
- Cited by
- 42
- References
- 0
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Excess tachycardia: heart rate after antimuscarinic agents in conscious dogs. https://app.cochat.ai/papers/10.1152/ajpheart.1984.246.2.h168
- The paper
- Rigel, D. F., Lipson, D., & Katona, P. G. (1984). Excess tachycardia: heart rate after antimuscarinic agents in conscious dogs. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1984.246.2.h168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.