CoChat

Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects.

The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.

Abstract

The correlations of 11 indexes of heart rate variability were examined with pharmacologically determined cardiac vagal tone in 15 normal subjects at supine rest. After sympathetic influences by intravenous propranolol were eliminated, RR interval variability was measured for 10 minutes under controlled respiration (0.25 Hz), and cardiac vagal tone was determined as the decrease in mean RR interval following complete vagal blockade with atropine. Time domain indexes (standard deviation, coefficient of variance and mean successive difference) correlated strongly with vagal tone (r = 0.87, 0.81 and 0.92, respectively; p less than 0.001 for all). The same was true for frequency domain indexes for the high-frequency (0.25 Hz) component calculated both by autoregressive spectrum analysis (square root of power and coefficient of component variance) and by fast Fourier transform (mean amplitude) (r = 0.91, 0.85 and 0.86, respectively; p less than 0.0001 for all). However, frequency domain indexes for the low-frequency spectral component (0.03 to 0.15 Hz) correlated less strongly (r = 0.69, 0.55 and 0.70, respectively), and the fraction of power [power/(total power greater than 0.03 Hz)] of both components showed no correlation. Principal component analysis showed that the first 6 indexes with strong correlations contained solely the first principal component closely related to vagal tone, whereas the remaining 5 indexes also contained the second component unrelated to vagal tone. These results indicate that most of the time and frequency domain analyses in use provides an accurate and common measure of cardiac vagal tone at rest.

Overview

Integrity signals

Registry

Crossref · 10.1016/0002-9149(91)90445-q

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Research works printed but not linked: 1

  1. Hayano, 1988, Autonomic nervous function and spectral components of heart rate variability, Seibutsubutsuri, 28, 32

Cited by

See all 746

Metadata

Authors
Hayano, J., Sakakibara, Y., Yamada, A., Yamada, M., Mukai, S., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K.
Affiliations
Nagoya City University (JP)
Corresponding author
Hayano, Junichiro
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
1991-01
Volume
67
Issue
2
Pages
199-204
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2040183537
Cited by
746
References
32
Citations by year
2026: 4 · 2025: 13 · 2024: 11 · 2023: 11 · 2022: 14 · 2021: 17 · 2020: 13 · 2019: 16 · 2018: 17 · 2017: 17 · 2016: 21 · 2015: 18 · 2014: 18 · 2013: 26 · 2012: 21
FWCI
13.30
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • The American Journal of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
cardiac vagal tone, heart rate variability, vagal blockade, atropine, propranolol, RR interval variability, high-frequency spectral components, fast Fourier transform, principal component analysis, autonomic nervous system
MeSH terms
Adult, Atropine, Autonomic Nervous System, Electrocardiography, Fourier Analysis, Heart, Heart Rate, Humans, Male, Propranolol, Reference Values, Regression Analysis, Vagus Nerve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects. https://app.cochat.ai/papers/10.1016/0002-9149(91)90445-q
The paper
Hayano, J., Sakakibara, Y., Yamada, A., Yamada, M., Mukai, S., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K. (1991). Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects. The American Journal of Cardiology. https://doi.org/10.1016/0002-9149(91)90445-q

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.