The DOI matches its Crossref record.
Filtration through damaged and undamaged rabbit thoracic aorta
Abstract
The influence of luminal pressure and endothelial removal on fluid filtration across the arterial wall has been studied in the rabbit thoracic aorta. Segments of aorta were excised in such a way as to prevent shortening and depressurization and were filled with a 4% albumin-Tyrode solution. Experiments were carried out at two controlled pressure levels (70 and 180 mmHg). The hydraulic conductivity (Lp) of the total wall, calculated from the filtration data, was 4.00 +/- 1.31 and 2.44 +/- 0.80 (SD) X 10(-8) cm/(s X mmHg) in intact wall at 70 and 180 mmHg, respectively (P less than 0.01), whereas values for deendothelialized arteries were higher (P less than 0.01), being 5.36 +/- 1.62 and 5.27 +/- 0.84, respectively. The apparent pressure dependence of conductivity of the intact wall may be due to altered strain of the interstitial matrix. Removal of the endothelium can increase the hydration and porosity of the medial interstitium but, assuming that the conductivity of the deendothelialized wall at 70 mmHg is the same as that of the normal media, the calculated conductivity of the endothelium is 15.76 X 10(-8) cm/(s . mmHg).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
FLOW THROUGH INTERSTITIUM AND OTHER FIBROUS MATRICES
Levick, J. R. (1987) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1987.sp003085 · Cited by 480
Saccular intracranial aneurysm: pathology and mechanisms
Frösen, J., Tulamo, R., Paetau, A., Laaksamo, E., Korja, M., Laakso, A., Niemelä, M., & Hernesniemi, J. (2012) · Acta Neuropathologica · doi:10.1007/s00401-011-0939-3 · Cited by 478
Mass Transport in Arteries and the Localization of Atherosclerosis
Tarbell, J. M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121529 · Cited by 281
Computational analysis of coupled blood-wall arterial LDL transport
Stangeby, D. K., & Ethier, C. R. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427041 · Cited by 154
Is bulk flow plausible in perivascular, paravascular and paravenous channels?
Faghih, M. M., & Sharp, M. K. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0103-8 · Cited by 101
Metadata
- Authors
- Tedgui, A., & Lever, M. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1984-11-01
- Volume
- 247
- Issue
- 5
- Pages
- H784-H791
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2413522437
- Cited by
- 187
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Filtration through damaged and undamaged rabbit thoracic aorta. https://app.cochat.ai/papers/10.1152/ajpheart.1984.247.5.h784
- The paper
- Tedgui, A., & Lever, M. J. (1984). Filtration through damaged and undamaged rabbit thoracic aorta. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1984.247.5.h784
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.