Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,292

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Hemodynamic regulation: investigation by spectral analysis

Akselrod, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., Cohen, R. J.·1985·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

We investigated the hypothesis that beat-to-beat variability in hemodynamic parameters reflects the dynamic interplay between ongoing perturbations to circulatory function and the compensatory response of short-term cardiovascular control systems. Spontaneous fluctuations in heart rate (HR), arterial blood pressure, and respiration were analyzed by spectral analysis in the 0.02- to 1-Hz frequency range. A simple closed-loop model of short-term cardiovascular control was proposed and evaluated in a series of experiments: pharmacological blockades of the parasympathetic, alpha-sympathetic, beta-sympathetic, and renin-angiotensin systems were used to open the principal control loops in order to examine changes in the spectral pattern of the fluctuations. Atrial pacing was used to examine blood pressure variability in the absence of HR variability. We found that respiratory frequency fluctuations in HR are parasympathetically mediated and that blood pressure fluctuations at this frequency result almost entirely from the direct effect of centrally mediated HR fluctuations. The sympathetic nervous system appears to be too sluggish to mediate respiratory frequency variations. Low-frequency (0.02-0.09 Hz) fluctuations in HR are jointly mediated by the parasympathetic and beta-sympathetic systems and appear to compensate for blood pressure fluctuations at this frequency. Low-frequency blood pressure fluctuations are probably due to variability in vasomotor activity which is normally damped by renin-angiotensin system activity. Blockade of the alpha-adrenergic system, however, does not significantly alter low-frequency blood pressure fluctuations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1985.249.4.h867

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 1,292

Metadata

Authors
Akselrod, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., & Cohen, R. J.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1985-10-01
Volume
249
Issue
4
Pages
H867-H875
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2158361166
Cited by
1,292
References
5
FWCI
5.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamic regulation: investigation by spectral analysis. https://app.cochat.ai/papers/10.1152/ajpheart.1985.249.4.h867
The paper
Akselrod, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., & Cohen, R. J. (1985). Hemodynamic regulation: investigation by spectral analysis. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1985.249.4.h867

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.