The DOI matches its Crossref record.
Microvascular distribution of coronary vascular resistance in beating left ventricle
Abstract
To determine the distribution of resistance in the coronary vasculature, measurements of microvascular pressure and diameter were obtained with vasomotor tone intact and during coronary dilation produced by papaverine. We studied anesthetized, open-chest cats and used jet ventilation synchronized to the cardiac cycle to eliminate respiratory-induced cardiac motion. The system for measuring microvascular pressure compensated for cardiac motion with stroboscopic illumination of the microvessels and a computer-controlled electromechanical micromanipulator that moved a micropipette in synchrony with the heart. Pressures were measured with the servonull technique, and diameters were measured via a video system. Resistance was estimated from the pressure gradient from the aorta to a particular class (size) of coronary microvessel. During control conditions, with coronary vasomotor tone intact, myocardial perfusion was 139 +/- 9 ml X min-1 X 100 g-1 and was increased to 339 +/- 52 during papaverine infusion (P less than 0.05). During control conditions (mean arterial pressure 70-80 mmHg), approximately 25% of total coronary resistance was proximal to 200-microns diameter arterioles and approximately 20% was produced by arterioles between 100 and 200 microns diameter; there was approximately 20-mmHg pressure gradient from the aorta to 200-microns arterioles and a 30- to 35-mmHg gradient from the aorta to 100-microns arterioles. Present results also indicate that 55% of total coronary resistance is distal to the 100-microns arterioles under control conditions. Coronary vasodilation with papaverine (mean arterial pressure maintained at 70-75 mmHg with an aortic snare) produced a redistribution of resistance; only 10% of total resistance was proximal to the 200-microns arterioles, and the pressure gradient from the aorta to these vessels was only 5-10 mmHg. Thus, under these experimental conditions with vasomotor tone intact, a substantial portion (45%) of coronary resistance resides in relatively large (greater than 100-microns) coronary arterioles, and the distribution of resistance and microvascular pressures can be shifted with coronary vasodilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Regulation of coronary blood flow during exercise
Duncker, D. J., & Bache, R. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00045.2006 · Cited by 936
Titheradge, M. A. (1999) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(99)00031-6 · Cited by 457
Quyyumi, A. A., Dakak, N., Andrews, N. P., Husain, S., Arora, S., Gilligan, D. M., Panza, J. A., & Cannon, R. O. (1995) · Journal of Clinical Investigation · doi:10.1172/jci117852 · Cited by 444
Mechanisms of angina pectoris in syndrome X
Maseri, A., Crea, F., Kaski, J. C., & Crake, T. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80122-6 · Cited by 424
Antzelevitch, C., Sun, Z.-Q., Zhang, Z.-Q., & Yan, G.-X. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00377-4 · Cited by 278
Metadata
- Authors
- Chilian, W. M., Eastham, C. L., & Marcus, M. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1986-10-01
- Volume
- 251
- Issue
- 4
- Pages
- H779-H788
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2203419598
- Cited by
- 378
- References
- 0
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular distribution of coronary vascular resistance in beating left ventricle. https://app.cochat.ai/papers/10.1152/ajpheart.1986.251.4.h779
- The paper
- Chilian, W. M., Eastham, C. L., & Marcus, M. L. (1986). Microvascular distribution of coronary vascular resistance in beating left ventricle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1986.251.4.h779
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.