Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 378

The DOI matches its Crossref record.

Microvascular distribution of coronary vascular resistance in beating left ventricle

Chilian, W. M., Eastham, C. L., Marcus, M. L.·1986·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

To determine the distribution of resistance in the coronary vasculature, measurements of microvascular pressure and diameter were obtained with vasomotor tone intact and during coronary dilation produced by papaverine. We studied anesthetized, open-chest cats and used jet ventilation synchronized to the cardiac cycle to eliminate respiratory-induced cardiac motion. The system for measuring microvascular pressure compensated for cardiac motion with stroboscopic illumination of the microvessels and a computer-controlled electromechanical micromanipulator that moved a micropipette in synchrony with the heart. Pressures were measured with the servonull technique, and diameters were measured via a video system. Resistance was estimated from the pressure gradient from the aorta to a particular class (size) of coronary microvessel. During control conditions, with coronary vasomotor tone intact, myocardial perfusion was 139 +/- 9 ml X min-1 X 100 g-1 and was increased to 339 +/- 52 during papaverine infusion (P less than 0.05). During control conditions (mean arterial pressure 70-80 mmHg), approximately 25% of total coronary resistance was proximal to 200-microns diameter arterioles and approximately 20% was produced by arterioles between 100 and 200 microns diameter; there was approximately 20-mmHg pressure gradient from the aorta to 200-microns arterioles and a 30- to 35-mmHg gradient from the aorta to 100-microns arterioles. Present results also indicate that 55% of total coronary resistance is distal to the 100-microns arterioles under control conditions. Coronary vasodilation with papaverine (mean arterial pressure maintained at 70-75 mmHg with an aortic snare) produced a redistribution of resistance; only 10% of total resistance was proximal to the 200-microns arterioles, and the pressure gradient from the aorta to these vessels was only 5-10 mmHg. Thus, under these experimental conditions with vasomotor tone intact, a substantial portion (45%) of coronary resistance resides in relatively large (greater than 100-microns) coronary arterioles, and the distribution of resistance and microvascular pressures can be shifted with coronary vasodilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1986.251.4.h779

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 378

Metadata

Authors
Chilian, W. M., Eastham, C. L., & Marcus, M. L.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1986-10-01
Volume
251
Issue
4
Pages
H779-H788
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2203419598
Cited by
378
References
0
FWCI
7.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microvascular distribution of coronary vascular resistance in beating left ventricle. https://app.cochat.ai/papers/10.1152/ajpheart.1986.251.4.h779
The paper
Chilian, W. M., Eastham, C. L., & Marcus, M. L. (1986). Microvascular distribution of coronary vascular resistance in beating left ventricle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1986.251.4.h779

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.