The DOI matches its Crossref record.
Laser-Doppler assessment of brain microcirculation: effect of systemic alterations
Abstract
There is a need for new technical approaches whereby the cerebral microcirculation can be easily and continuously assessed. The objective of this study was to determine whether laser-Doppler (LD) flowmetry can be utilized to assess changes in cerebral cortical blood flow and to determine whether changes in blood perfusion measured by LD flowmetry correlate with simultaneously measured changes in flow measured by H2 clearance in cats or with changes in pial arteriolar diameter measured with a microscope in rabbits equipped with a closed cranial window. In the rabbit experiments a 0.84-mm-diam LD probe was inserted through a cranial window port, and in the cat experiments the probe was fixed adjacent to the H2 probe. The probe was fixed at a distance of 1-2 mm from the cortical surface, where it and its associated electronics detect changes in blood cell velocity and blood volume within a tissue volume of approximately 1 mm3. Volume and velocity are multiplied to provide a flow signal. When cerebral blood flow in cats was decreased by hyperventilation-induced hypocapnia and increased by norepinephrine-induced hypertension, the percent changes in LD flow and H2 clearance flow changed linearly (r = 0.94, slope = 0.97). When arterial PCO2 was increased from 28 to 48 mmHg in the rabbit experiments, the pial arterioles dilated 19 +/- 4% (mean +/- SE) and LD flow increased by 74 +/- 9%, LD flow changes which would be predicted by a third power relationship of diameter to flow.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Malonek, D., Dirnagl, U., Lindauer, U., Yamada, K., Kanno, I., & Grinvald, A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.26.14826 · Cited by 443
Yang, G. Y., & Betz, A. L. (1994) · Stroke · doi:10.1161/01.str.25.8.1658 · Cited by 333
Mayevsky, A., Doron, A., Manor, T., Meilin, S., Zarchin, N., & Ouaknine, G. E. (1996) · Brain Research · doi:10.1016/s0006-8993(96)00874-8 · Cited by 280
Monitoring of autoregulation using laser Doppler flowmetry in patients with head injury
Lam, J. M. K., Hsiang, J. N. K., & Poon, W. S. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.86.3.0438 · Cited by 150
Metadata
- Authors
- Haberl, R. L., Heizer, M. L., Marmarou, A., & Ellis, E. F.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-04-01
- Volume
- 256
- Issue
- 4
- Pages
- H1247-H1254
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1876758225
- Cited by
- 218
- References
- 0
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laser-Doppler assessment of brain microcirculation: effect of systemic alterations. https://app.cochat.ai/papers/10.1152/ajpheart.1989.256.4.h1247
- The paper
- Haberl, R. L., Heizer, M. L., Marmarou, A., & Ellis, E. F. (1989). Laser-Doppler assessment of brain microcirculation: effect of systemic alterations. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1989.256.4.h1247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.