The DOI matches its Crossref record.
Leukocyte margination and deformation in mesenteric venules of rat
Abstract
White blood cell (WBC) margination and rolling were studied in venules (20-60 microns in diameter) in rat mesentery to examine the relationship between WBC rolling velocity (Vwbc), flux (Fwbc, cells/min), and deformation; and red blood cell (RBC) velocity (Vrbc), wall shear rate (gamma), and microvessel hematocrit (Hmicro). For a range of 1.0 less than or equal to Vrbc less than or equal to 5.0 mm/s, Vwbc remained constant (congruent to 50 microns/s). The volume flux of WBCs rolling along the venular wall (normalized to systemic WBC concentration) decreased nonlinearly from 30 to 5% of total luminal flux as gamma ranged from 50 to 800 s-1 and was more strongly correlated with gamma compared with Fwbc vs. gamma. As indicated by the rolling volumetric flux, margination was weakly affected by Hmicro, except for Hmicro greater than 50% where margination increased. Deformation of WBCs was quantitated during their rolling contact with the endothelium (EC) in terms of their length and height. As gamma increased from 50 to 800 s-1, WBCs elongated to 140% of their estimated undeformed diameter, and the contact area between WBC and EC increased 3.6-fold. These data suggest that with increased gamma rolling of WBCs along the EC decreases, since only the most deformable WBCs of the circulating population persist in maintaining contact with the endothelium. It is concluded that Vwbc is invariant with elevations in gamma, since the greater deformations of rolling WBCs at high shear result in greater adhesive forces attendant to increased WBC-EC contact area, which attenuate increases in Vwbc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lymphocyte Homing and Homeostasis
Butcher, E. C., & Picker, L. J. (1996) · Science · doi:10.1126/science.272.5258.60 · Cited by 2,846
Blood Rheology and Hemodynamics
(2003) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2003-44551 · Cited by 1,006
The microcirculation and inflammation: modulation of leukocyte-endothelial cell adhesion
Granger, D. N., & Kubes, P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.5.662 · Cited by 849
Grace, P. A. (1994) · Journal of British Surgery · doi:10.1002/bjs.1800810504 · Cited by 720
Multifunctional surface microrollers for targeted cargo delivery in physiological blood flow
Alapan, Y., Bozuyuk, U., Erkoc, P., Karacakol, A. C., & Sitti, M. (2020) · Science Robotics · doi:10.1126/scirobotics.aba5726 · Cited by 414
Metadata
- Authors
- Firrell, J. C., & Lipowsky, H. H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-06-01
- Volume
- 256
- Issue
- 6
- Pages
- H1667-H1674
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1862647003
- Cited by
- 211
- References
- 0
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Leukocyte margination and deformation in mesenteric venules of rat. https://app.cochat.ai/papers/10.1152/ajpheart.1989.256.6.h1667
- The paper
- Firrell, J. C., & Lipowsky, H. H. (1989). Leukocyte margination and deformation in mesenteric venules of rat. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1989.256.6.h1667
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.