Leukocyte margination and deformation in mesenteric venules of rat
The DOI matches its Crossref record.
Abstract
White blood cell (WBC) margination and rolling were studied in venules (20-60 microns in diameter) in rat mesentery to examine the relationship between WBC rolling velocity (Vwbc), flux (Fwbc, cells/min), and deformation; and red blood cell (RBC) velocity (Vrbc), wall shear rate (gamma), and microvessel hematocrit (Hmicro). For a range of 1.0 less than or equal to Vrbc less than or equal to 5.0 mm/s, Vwbc remained constant (congruent to 50 microns/s). The volume flux of WBCs rolling along the venular wall (normalized to systemic WBC concentration) decreased nonlinearly from 30 to 5% of total luminal flux as gamma ranged from 50 to 800 s-1 and was more strongly correlated with gamma compared with Fwbc vs. gamma. As indicated by the rolling volumetric flux, margination was weakly affected by Hmicro, except for Hmicro greater than 50% where margination increased. Deformation of WBCs was quantitated during their rolling contact with the endothelium (EC) in terms of their length and height. As gamma increased from 50 to 800 s-1, WBCs elongated to 140% of their estimated undeformed diameter, and the contact area between WBC and EC increased 3.6-fold. These data suggest that with increased gamma rolling of WBCs along the EC decreases, since only the most deformable WBCs of the circulating population persist in maintaining contact with the endothelium. It is concluded that Vwbc is invariant with elevations in gamma, since the greater deformations of rolling WBCs at high shear result in greater adhesive forces attendant to increased WBC-EC contact area, which attenuate increases in Vwbc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lymphocyte Homing and Homeostasis
Butcher, E. C., & Picker, L. J. (1996) · Science · doi:10.1126/science.272.5258.60 · Cited by 2,846
Blood Rheology and Hemodynamics
(2003) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2003-44551 · Cited by 1,006
The microcirculation and inflammation: modulation of leukocyte-endothelial cell adhesion
Granger, D. N., & Kubes, P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.5.662 · Cited by 849
Grace, P. A. (1994) · Journal of British Surgery · doi:10.1002/bjs.1800810504 · Cited by 720
Sequential contribution of L- and P-selectin to leukocyte rolling in vivo.
Ley, K., Bullard, D. C., Arbonés, M. L., Bosse, R., Vestweber, D., Tedder, T. F., & Beaudet, A. L. (1995) · The Journal of experimental medicine · doi:10.1084/jem.181.2.669 · Cited by 574
Multifunctional surface microrollers for targeted cargo delivery in physiological blood flow
Alapan, Y., Bozuyuk, U., Erkoc, P., Karacakol, A. C., & Sitti, M. (2020) · Science Robotics · doi:10.1126/scirobotics.aba5726 · Cited by 414
A central role for microvillous receptor presentation in leukocyte adhesion under flow
von Andrian, U. H., Hasslen, S. R., Nelson, R. D., Erlandsen, S. L., & Butcher, E. C. (1995) · Cell · doi:10.1016/0092-8674(95)90278-3 · Cited by 370
The Kinetics of L-selectin Tethers and the Mechanics of Selectin-mediated Rolling
Alon, R., Chen, S., Puri, K. D., Finger, E. B., & Springer, T. A. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.138.5.1169 · Cited by 352
Kunkel, E. J., & Ley, K. (1996) · Circulation Research · doi:10.1161/01.res.79.6.1196 · Cited by 328
Role of glycocalyx in leukocyte-endothelial cell adhesion
Mulivor, A. W., & Lipowsky, H. H. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00117.2002 · Cited by 328
Self-citationTissue factor–positive neutrophils bind to injured endothelial wall and initiate thrombus formation
Darbousset, R., Thomas, G. M., Mezouar, S., Frère, C., Bonier, R., Mackman, N., Renné, T., Dignat-George, F., Dubois, C., & Panicot-Dubois, L. (2012) · Blood · doi:10.1182/blood-2012-06-437772 · Cited by 323
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
E-selectin supports neutrophil rolling in vitro under conditions of flow.
Abbassi, O., Kishimoto, T. K., McIntire, L. V., Anderson, D. C., & Smith, C. W. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116889 · Cited by 262
Ley, K., & Gaehtgens, P. (1991) · Circulation Research · doi:10.1161/01.res.69.4.1034 · Cited by 258
Schmid-Schönbein, G. W. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095708 · Cited by 253
Perry, M. A., & Granger, D. N. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115200 · Cited by 250
“0 mm/s, while Firrell & Lipowsky (2) found that Vwbz remained constant once V.”
BackgroundIntegration of inflammatory signals by rolling neutrophils
Ley, K. (2002) · Immunological Reviews · doi:10.1034/j.1600-065x.2002.18602.x · Cited by 242
Synthesis, Functionalization, and Design of Magnetic Nanoparticles for Theranostic Applications
Mosayebi, J., Kiyasatfar, M., & Laurent, S. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700306 · Cited by 241
Catch bonds govern adhesion through L-selectin at threshold shear
Yago, T., Wu, J., Wey, C. D., Klopocki, A. G., Zhu, C., & McEver, R. P. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200403144 · Cited by 229
“These cellular properties may include deformation that increases the adhesive contact area, facilitating new bonds that distribute the applied force, and extrusion of long membrane tethers that reduce the tether angle and thus the tether force (Firrell and Lipowsky, 1989; Shao et al., 1998; Lei et al., 1999; Schmidtke…”
BackgroundTRAIL-coated leukocytes that kill cancer cells in the circulation
Mitchell, M. J., Wayne, E., Rana, K., Schaffer, C. B., & King, M. R. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316312111 · Cited by 213
“Highly deformable erythrocytes experience a drift velocity away from the vessel wall and collect in the center region, displacing less deformable leukocytes and CTCs to the near-wall region in a mechanism termed margination (14).”
BackgroundIntravital Microscopy of the Peripheral Lymph Node Microcirculation in Mice
Von Andrian, U. H. (1996) · Microcirculation · doi:10.3109/10739689609148303 · Cited by 206
Mechanism of Margination in Confined Flows of Blood and Other Multicomponent Suspensions
Kumar, A., & Graham, M. D. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.108102 · Cited by 185
‘Slings’ enable neutrophil rolling at high shear
Sundd, P., Gutierrez, E., Koltsova, E. K., Kuwano, Y., Fukuda, S., Pospieszalska, M. K., Groisman, A., & Ley, K. (2012) · Nature · doi:10.1038/nature11248 · Cited by 181
The expression of P- and E-selectins in three models of middle cerebral artery occlusion
Zhang, R., Chopp, M., Zhang, Z., Jiang, N., & Powers, C. (1998) · Brain Research · doi:10.1016/s0006-8993(97)01343-7 · Cited by 167
Metadata
- Authors
- Firrell, J. C., & Lipowsky, H. H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-06-01
- Volume
- 256
- Issue
- 6
- Pages
- H1667-H1674
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1862647003
- Cited by
- 211
- References
- 0
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.