Dynamic changes in cardiac vagal tone as measured by time-series analysis
The DOI matches its Crossref record.
Abstract
A time-series analysis of heart rate variability was evaluated as a marker of cardiac vagal tone using well-characterized autonomic interventions. Heart period (R-R interval) was recorded in 14 mongrel dogs from which the amplitude of the respiratory sinus arrhythmia (0.24-1.04 Hz) was determined. Exercise elicited significant (P less than 0.01) reductions in the index of vagal tone (control 6.3 +/- 0.3 ln ms2 vs. exercise 2.4 +/- 0.4 ln ms2) that were accompanied by significant (P less than 0.01) increases in heart rate (control 123.1 +/- 5 vs. exercise 201.0 +/- 7.7 beats/min). The vagal tone index remained greater than 0 throughout exercise. After propranolol HCl pretreatment, the vagal tone index rapidly decreased toward zero (control 6.2 +/- 0.5; exercise 0.7 +/- 0.3 ln ms2), despite significantly lower increases in heart rate (control 109.3 +/- 4.2; exercise 178.0 +/- 7.6 beats/min). Atropine given during exercise evoked significantly greater increases in heart rate in the control (+48.7 +/- 7.9 beats/min) vs. propranolol (+14.2 +/- 6.7 beats/min) conditions. These data suggest that 1) high levels of cardiac vagal tone remain during exercise; 2) vagal withdrawal is largely responsible for the heart rate increase after beta-adrenergic receptor blockade; and 3) time-series analysis of the R-R interval can provide a dynamic and noninvasive index of cardiac vagal tone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PORGES, S. W. (1995) · Psychophysiology · doi:10.1111/j.1469-8986.1995.tb01213.x · Cited by 1,624
The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance
Billman, G. E. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00026 · Cited by 1,401
Self-citationHeart rate variability: measurement and clinical utility.
Kleiger, R. E., Stein, P. K., & Bigger, J. T. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.10101.x · Cited by 1,290
BERNTSON, G. G., CACIOPPO, J. T., & QUIGLEY, K. S. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb01731.x · Cited by 998
Heart Rate Variability ? A Historical Perspective
Billman, G. E. (2011) · Frontiers in Physiology · doi:10.3389/fphys.2011.00086 · Cited by 786
Self-citation
Metadata
- Authors
- Billman, G. E., & Dujardin, J. P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1990-03-01
- Volume
- 258
- Issue
- 3
- Pages
- H896-H902
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2216582527
- Cited by
- 96
- References
- 0
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic changes in cardiac vagal tone as measured by time-series analysis. https://app.cochat.ai/papers/10.1152/ajpheart.1990.258.3.h896
- The paper
- Billman, G. E., & Dujardin, J. P. (1990). Dynamic changes in cardiac vagal tone as measured by time-series analysis. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1990.258.3.h896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.