Mathematical model of geometry and fibrous structure of the heart
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We developed a mathematical representation of ventricular geometry and muscle fiber organization using three-dimensional finite elements referred to a prolate spheroid coordinate system. Within elements, fields are approximated using basis functions with associated parameters defined at the element nodes. Four parameters per node are used to describe ventricular geometry. The radial coordinate is interpolated using cubic Hermite basis functions that preserve slope continuity, while the angular coordinates are interpolated linearly. Two further nodal parameters describe the orientation of myocardial fibers. The orientation of fibers within coordinate planes bounded by epicardial and endocardial surfaces is interpolated linearly, with transmural variation given by cubic Hermite basis functions. Left and right ventricular geometry and myocardial fiber orientations were characterized for a canine heart arrested in diastole and fixed at zero transmural pressure. The geometry was represented by a 24-element ensemble with 41 nodes. Nodal parameters fitted using least squares provided a realistic description of ventricular epicardial [root mean square (RMS) error less than 0.9 mm] and endocardial (RMS error less than 2.6 mm) surfaces. Measured fiber fields were also fitted (RMS error less than 17 degrees) with a 60-element, 99-node mesh obtained by subdividing the 24-element mesh. These methods provide a compact and accurate anatomic description of the ventricles suitable for use in finite element stress analysis, simulation of cardiac electrical activation, and other cardiac field modeling problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
Left ventricular fibre architecture in man.
Greenbaum, R. A., Ho, S. Y., Gibson, D. G., Becker, A. E., & Anderson, R. H. (1981) · Heart · doi:10.1136/hrt.45.3.248 · Cited by 1,074
Finite elements and approximation
Zienkiewicz, O. C., & Morgan, K. (1983) · UCLA Biblioteca de Ingenieria Civil · Cited by 888
Roberts, D. E., Hersh, L. T., & Scher, A. M. (1979) · Circulation Research · doi:10.1161/01.res.44.5.701 · Cited by 437
Gross morphology and fiber geometry of the heart
Streeter, D. D. (1979) · Medical Entomology and Zoology · Cited by 430
Yin, F. C. (1981) · Circulation Research · doi:10.1161/01.res.49.4.829 · Cited by 374
STREETER, D. D., & HANNA, W. T. (1973) · Circulation Research · doi:10.1161/01.res.33.6.639 · Cited by 222
FALSETTI, H. L., MATES, R. E., GRANT, C., GREENE, D. G., & BUNNELL, I. L. (1970) · Circulation Research · doi:10.1161/01.res.26.1.71 · Cited by 209
Yin, F. C. P., Strumpf, R. K., Chew, P. H., & Zeger, S. L. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90279-x · Cited by 203
On the muscular architecture of the ventricles of the human heart
Mall, F. P. (1911) · American Journal of Anatomy · doi:10.1002/aja.1000110302 · Cited by 194
The analysis of cardiac function: A continuum approach
Hunter, P. J., & Smaill, B. H. (1988) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(88)90004-1 · Cited by 191
Self-citationAn engineering analysis of myocardial fiber orientation in pig's left ventricle in systole
Streeter, D. D., & Bassett, D. L. (1966) · The Anatomical Record · doi:10.1002/ar.1091550403 · Cited by 182
Architecture of the human ventricular myocardium
Fox, C. C., & Hutchins, G. M. (1949) · American Heart Journal · doi:10.1016/0002-8703(49)91220-x · Cited by 90
Structure and Function of the Diastolic Heart: Material Properties of Passive Myocardium
Smaill, B. H., & Hunter, P. J. (1991) · Institute for Nonlinear Science · doi:10.1007/978-1-4612-3118-9_1 · Cited by 86
Self-citationThree‐dimensional reconstruction of the myofiber pattern in the fetal and neonatal mouse heart
McLean, M. R., Ross, M. A., & Prothero, J. W. (1989) · The Anatomical Record · doi:10.1002/ar.1092240308 · Cited by 28
Computer Modeling of the Human Left Ventricle
Yettram, A. L., Vinson, C. A., & Gibson, D. G. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138329 · Cited by 20
Cited by
Fenton, F., & Karma, A. (1998) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166311 · Cited by 862
A simple two-variable model of cardiac excitation
Aliev, R. R., & Panfilov, A. V. (1996) · Chaos, Solitons & Fractals · doi:10.1016/0960-0779(95)00089-5 · Cited by 786
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Tagantsev, A. K., Stolichnov, I., Colla, E. L., & Setter, N. (2001) · Journal of Applied Physics · doi:10.1063/1.1381542 · Cited by 602
Models of cardiac tissue electrophysiology: Progress, challenges and open questions
Clayton, R. H., Bernus, O., Cherry, E. M., Dierckx, H., Fenton, F. H., Mirabella, L., Panfilov, A. V., Sachse, F. B., Seemann, G., & Zhang, H. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.05.008 · Cited by 585
Metadata
- Authors
- Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1991-04-01
- Volume
- 260
- Issue
- 4
- Pages
- H1365-H1378
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2161629941
- Cited by
- 657
- References
- 16
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.