CoChat

Trabecular smooth muscle modulates the capacitor function of the penis. Studies on a rabbit model

Saenz de Tejada, I., Moroukian, P., Tessier, J., Kim, J. J., Goldstein, I., Frohrib, D. · 1991 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 147

The DOI matches its Crossref record.

Abstract

We investigated the role of trabecular smooth muscle tone in regulation of intracavernosal pressure, venous outflow resistance, and penile capacitance. In an isolated rabbit whole penis model, corpora cavernosa were infused with either contracting (high K(+)-norepinephrine combination) or relaxing (no added Ca(2+)-papaverine combination) physiological salt solutions while intracavernosal pressure was recorded. An infusion pump regulated by an intracavernosal pressure feedback mechanism enabled the measurement of flow necessary to maintain intracavernosal pressures at 30, 60, 90, 120, and 150 mmHg under steady-state conditions (inflow = outflow). These experiments allowed resistance to outflow from corpora to be calculated when trabecular smooth muscle was either constricted or relaxed. Decay in intracavernosal pressure over time from various predetermined intracavernosal pressures (150, 120, 90, 60, and 30 mmHg) was studied under conditions of zero inflow following contraction or relaxation of trabecular smooth muscle. This permitted calculation of the time constant, which together with the outflow resistance, permitted the calculation of penile capacitance. When smooth muscle is relaxed, venous outflow resistance is high, constant, and independent of intracavernosal pressure. Furthermore, relaxation of smooth muscle allows expansion of corpora with accumulation of volume under pressure, enabling the penis to act as a capacitor. This capacitor function is limited in the presence of constant high outflow resistance by stiffness of the fibroelastic elements of penis, tunica, and fibroelastic frame, which exhibit nonlinear deflection trends. Analysis of these variables has led us to propose a model for penile erection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1991.260.5.h1590

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 147

Metadata

Authors
Saenz de Tejada, I., Moroukian, P., Tessier, J., Kim, J. J., Goldstein, I., & Frohrib, D.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1991-05-01
Volume
260
Issue
5
Pages
H1590-H1595
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2179093552
Cited by
147
References
0
FWCI
2.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trabecular smooth muscle modulates the capacitor function of the penis. Studies on a rabbit model. https://app.cochat.ai/papers/10.1152/ajpheart.1991.260.5.h1590
The paper
Saenz de Tejada, I., Moroukian, P., Tessier, J., Kim, J. J., Goldstein, I., & Frohrib, D. (1991). Trabecular smooth muscle modulates the capacitor function of the penis. Studies on a rabbit model. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1991.260.5.h1590

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.