The DOI matches its Crossref record.
Release of endothelium-derived relaxing factor is modulated both by frequency and amplitude of pulsatile flow
Abstract
We have dissociated the effects of frequency and amplitude of pulsatile flow on flow-induced release of endothelium-derived relaxing factor (EDRF) using cascade bioassay. Rat aortic segments were buffer perfused with a peristaltic pump at a constant mean flow rate of 9 ml/min. EDRF activity in effluent was measured by relaxation of endothelium-denuded rabbit aortic rings preconstricted by phenylephrine. Pulse frequency was varied over the range 0.1-12 Hz at a constant amplitude of 2 mmHg; pulse amplitude was varied over the range 2-16 mmHg at a constant frequency of 0.1 Hz. Relaxation of the detector vessel depended on frequency of flow through the donor; peak response occurred between 4.2 and 6 Hz and was approximately three times greater than that induced at lower or higher frequencies. In contrast, increases in pulse pressure amplitude (maximum 16 mmHg) monotonically augmented constriction of partially preconstricted detector tissue by up to 10%. Incubation of the donor vessel with NG-nitro-L-arginine methyl ester (L-NAME), an inhibitor of nitric oxide synthesis, or removal of its endothelium by rubbing, abolished both the frequency- and the amplitude-dependent effects observed in the detector tissue, indicating that these were mediated by changes in EDRF release. Increasing the amplitude of the pressure pulse also reduced mean perfusion pressure (by up to 50%), implying distension of donor vessel since mean flow rate was constant. This fall in pressure was not affected by incubation with L-NAME or removal of endothelium, indicating that it was not dependent on EDRF activity.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483
Effect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Benjamin, E. J., Larson, M. G., Keyes, M. J., Mitchell, G. F., Vasan, R. S., Keaney, J. F., Lehman, B. T., Fan, S., Osypiuk, E., & Vita, J. A. (2004) · Circulation · doi:10.1161/01.cir.0000112565.60887.1e · Cited by 607
Flow-Mediated Dilation and Cardiovascular Event Prediction: Does Nitric Oxide Matter?
Green, D. J., Jones, H., Thijssen, D., Cable, N. T., & Atkinson, G. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.167015 · Cited by 557
Metadata
- Authors
- Hutcheson, I. R., & Griffith, T. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1991-07-01
- Volume
- 261
- Issue
- 1
- Pages
- H257-H262
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2341645605
- Cited by
- 207
- References
- 0
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Release of endothelium-derived relaxing factor is modulated both by frequency and amplitude of pulsatile flow. https://app.cochat.ai/papers/10.1152/ajpheart.1991.261.1.h257
- The paper
- Hutcheson, I. R., & Griffith, T. M. (1991). Release of endothelium-derived relaxing factor is modulated both by frequency and amplitude of pulsatile flow. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1991.261.1.h257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.