CoChat

Role of sinoaortic afferents in modulating BP and pulse-interval spectral characteristics in unanesthetized cats

Di Rienzo, M., Parati, G., Castiglioni, P., Omboni, S., Ferrari, A. U., Ramirez, A. J., Pedotti, A., Mancia, G. · 1991 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 111

The DOI matches its Crossref record.

Abstract

Sinoaortic denervation (SAD) is accompanied by an increase in blood pressure (BP) and a reduction in pulse-interval (PI) variance. Little is known, however, about the effect of SAD on the complex BP and PI variability pattern, which is identified by spectral analysis. In nine unanesthetized cats in which intra-arterial BP was monitored before and 7-10 days after SAD, spectral powers (estimated by fast Fourier transform) were calculated for the low frequency (LF, 0.025-0.07 Hz), midfrequency (MF, 0.07-0.14 Hz), and high frequency (HF, 0.14-0.60 Hz) band. The very low frequency (VLF) BP and PI components (VLF less than 0.025 Hz) were also estimated. SAD increased systolic BP variance and decreased PI variance. The reduction of PI variance was paralleled by significant and marked reductions in all PI powers including the VLF components. In contrast, the increase in systolic BP variance was accompanied by a marked increase in LF power, a decrease in MF power, and no change in HF power. The VLF BP components increased after SAD for frequencies between 0.025 and 0.0012 Hz, whereas a sudden marked reduction was observed below 0.0012 Hz. Similar results were obtained for diastolic BP powers. Thus the reduction in PI variance induced by SAD is paralleled by a reduction in all PI fluctuations identified by spectral analysis. This is not the case for the SAD-related increase in BP variance, which is accompanied by an increase, no change, or even a reduction in the different BP spectral components.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1991.261.6.h1811

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 111

Metadata

Authors
Di Rienzo, M., Parati, G., Castiglioni, P., Omboni, S., Ferrari, A. U., Ramirez, A. J., Pedotti, A., & Mancia, G.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1991-12-01
Volume
261
Issue
6
Pages
H1811-H1818
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2203191247
Cited by
111
References
0
FWCI
2.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Role of sinoaortic afferents in modulating BP and pulse-interval spectral characteristics in unanesthetized cats. https://app.cochat.ai/papers/10.1152/ajpheart.1991.261.6.h1811
The paper
Di Rienzo, M., Parati, G., Castiglioni, P., Omboni, S., Ferrari, A. U., Ramirez, A. J., Pedotti, A., & Mancia, G. (1991). Role of sinoaortic afferents in modulating BP and pulse-interval spectral characteristics in unanesthetized cats. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1991.261.6.h1811

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.