Distribution, propagation, and coordination of contractile activity in lymphatics
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The propagation and coordination of lymphatic contractions were studied in the mesentery of the rat small intestine using in situ microscopic observation. Indexes of lymphatic diameter were simultaneously measured at two adjacent lymphangions in spontaneously contracting lymphatics (n = 51). Diameter index, contraction frequency, and the percentage of the intersegmental contractions that were propagated and coordinated (PP) were determined at both sites. The conduction velocity of the contractile activity and the percentage of the coordinated contractions that were propagated both antegrade to the direction of lymph flow and retrograde to the flow stream were determined. The results indicate that 1) 80-90% of the lymphatic contractions in the vessels we evaluated were propagated, 2) the wave of contractile activity propagated both centrally and peripherally, and 3) the conduction velocity of the contractile activity was approximately 4-8 mm/s. We tested the hypothesis that gap junctional communication is responsible for the coordination of the contractile event. To accomplish this, we used the gap junction blockers n-heptanol and oleic acid. PP was 90 +/- 4% under normal conditions and fell to a minimum value of 55 +/- 7% during the gap junction blockade. These results indicate that gap junctional communication played an important role in the propagation and coordination of contractions that occurred in spontaneously active lymphatics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of transmural pressure on pumping activity in isolated bovine lymphatic vessels.
McHale, N. G., & Roddie, I. C. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011557 · Cited by 245
Conduction of vasomotor responses in arterioles: a role for cell-to-cell coupling?
Segal, S. S., & Duling, B. R. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.3.h838 · Cited by 212
Active and passive mechanical characteristics of bovine mesenteric lymphatics
Ohhashi, T., Azuma, T., & Sakaguchi, M. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.1.h88 · Cited by 179
Propagation of vasomotor responses coordinates arteriolar resistances
Segal, S. S., Damon, D. N., & Duling, B. R. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.3.h832 · Cited by 131
Nervous modulation of spontaneous contractions in bovine mesenteric lymphatics.
McHale, N. G., Roddie, I. C., & Thornbury, K. D. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013520 · Cited by 88
Segal, S. S., & Duling, B. R. (1987) · Circulation Research · doi:10.1161/res.61.5_supplement.ii-20 · Cited by 83
Active contractility of the lymphangion and coordination of lymphangion chains
Mislin, H. (1976) · Cellular and Molecular Life Sciences · doi:10.1007/bf02003701 · Cited by 49
Cholinergic and adrenergic innervation of mesenterial lymph vessels in guinea pig.
Alessandrini, C., Gerli, R., Sacchi, G., Ibba, L., Pucci, A., & Fruschelli, C. (1981) · PubMed · Cited by 47
Cited by
The physiology of the lymphatic system
Swartz, M. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00150-8 · Cited by 737
Lymphatic pumping: mechanics, mechanisms and malfunction
Scallan, J. P., Zawieja, S. D., Castorena‐Gonzalez, J. A., & Davis, M. J. (2016) · The Journal of Physiology · doi:10.1113/jp272088 · Cited by 424
“In mesenteric lymphatic vessel segments studied either ex vivo or in vivo, the application of gap-junction blockers (e.g. n-heptanol, oleic acid) leads to uncoordinated contractions of different parts of a lymphatic chain (McHale & Meharg, 1992; Zawieja et al. 1993).”
BackgroundContractile Physiology of Lymphatics
Zawieja, D. C. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2009.0007 · Cited by 368
Self-citationLymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Moore, J. E., & Bertram, C. D. (2018) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122316-045259 · Cited by 340
Metadata
- Authors
- Zawieja, D. C., Davis, K. L., Schuster, R., Hinds, W. M., & Granger, H. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1993-04-01
- Volume
- 264
- Issue
- 4
- Pages
- H1283-H1291
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2412848798
- Cited by
- 188
- References
- 8
- FWCI
- 0.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.