The DOI matches its Crossref record.
Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis
Abstract
Shear stress and alterations in blood flow within a stenosed artery promote platelet-dependent thrombosis. Using the Folts model of coronary thrombosis, we evaluated morphology, histology, and the hemodynamic properties of the stenosed vessel in 18 animals. The average stenosis created was 58 +/- 8%, with stenosed vessel diameters ranging from 0.084 to 0.159 cm. Histological examination of the stenosed vessel demonstrated that thrombi were composed primarily of platelets and formation occurred 1.0 mm downstream from the apex of the constriction, propagating distally. Peak shear stress occurred just upstream from the apex of the stenosis and varied from 520 to 3,349 dyn/cm2. Only small differences in shear forces were noted when blood viscosity was calculated using Newtonian and non-Newtonian properties. In contrast, shear stress computed for Poiseuille flow with use of the stenosis diameter underestimated the apical shear stress. Blood flow remained laminar within the stenosis with a Reynolds number range of 292-534. Our data indicate that the geometry of the stenosis inflow region must be considered in the evaluation of platelet activation and thrombus formation within a stenosed artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PI 3-kinase p110β: a new target for antithrombotic therapy
Jackson, S. P., Schoenwaelder, S. M., Goncalves, I., Nesbitt, W. S., Yap, C. L., Wright, C. E., Kenche, V., Anderson, K. E., Dopheide, S. M., Yuan, Y., et al. (2005) · Nature Medicine · doi:10.1038/nm1232 · Cited by 580
Fluid Mechanics of Vascular Systems, Diseases, and Thrombosis
Wootton, D. M., & Ku, D. N. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.299 · Cited by 559
Berger, S. A., & Jou, L.-D. (2000) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.32.1.347 · Cited by 502
Computational and Experimental Models of Cancer Cell Response to Fluid Shear Stress
Mitchell, M. J., & King, M. R. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00044 · Cited by 221
Resistance to Fluid Shear Stress Is a Conserved Biophysical Property of Malignant Cells
Barnes, J. M., Nauseef, J. T., & Henry, M. D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050973 · Cited by 203
Metadata
- Authors
- Strony, J., Beaudoin, A., Brands, D., & Adelman, B.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1993-11-01
- Volume
- 265
- Issue
- 5
- Pages
- H1787-H1796
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1926928802
- Cited by
- 200
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis. https://app.cochat.ai/papers/10.1152/ajpheart.1993.265.5.h1787
- The paper
- Strony, J., Beaudoin, A., Brands, D., & Adelman, B. (1993). Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1993.265.5.h1787
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.