The DOI matches its Crossref record.
Topology and dimensions of pig coronary capillary network
Abstract
To provide a morphometric basis for any mathematical modeling of the coronary vasculature, data on the network of coronary capillary blood vessels and the topology of the arteriolar supply and venular drainage relative to the capillaries are presented. The diameters, lengths, and branching patterns of the coronary capillary blood vessels in the right and left ventricles of four pigs were measured. The locations of the coronary arterioles and venules were identified, topological maps were constructed, and the mean functional length of capillaries connecting an arteriole to an adjacent venule was measured. The vasculature was fixed by perfusing the coronary vessels with a catalyzed polymer. After the polymer hardened, plugs of the myocardium were removed, sectioned, dehydrated, and cleared to render the capillary network visible in a light microscope. The capillaries then were traced by optical sectioning. We designated the capillaries as blood vessels of order number zero; we further designated the capillaries as those fed directly by arterioles (C0a), those drained directly into venules (C0v), and those capillary vessels connected to C0a and C0v. The capillaries are connected in patterns identified as Y, T, H, or hairpin and anastomosed through capillary cross-connections (Ccc). The Ccc vessels may connect adjacent capillaries or capillaries originating from different arterioles. The connection among the capillaries, arteries, and veins is presented in terms of a connectivity matrix. Combining the present data with those for the arterial and venous trees, we have obtained a complete set of statistical data of all the blood vessels of the heart of the pig. Such a data set will serve as the basis of coronary hemodynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Swine as Models in Biomedical Research and Toxicology Testing
Swindle, M. M., Makin, A., Herron, A. J., Clubb, F. J., & Frazier, K. S. (2012) · Veterinary Pathology · doi:10.1177/0300985811402846 · Cited by 1,357
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Johnston, P. V., Sasano, T., Mills, K., Evers, R., Lee, S.-T., Smith, R. R., Lardo, A. C., Lai, S., Steenbergen, C., Gerstenblith, G., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.816058 · Cited by 413
Hunter, P. J., Pullan, A. J., & Smaill, B. H. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121537 · Cited by 291
Cross-Talk Between Cardiac Muscle and Coronary Vasculature
Westerhof, N., Boer, C., Lamberts, R. R., & Sipkema, P. (2006) · Physiological Reviews · doi:10.1152/physrev.00029.2005 · Cited by 270
Metadata
- Authors
- Kassab, G. S., & Fung, Y. C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1994-07-01
- Volume
- 267
- Issue
- 1
- Pages
- H319-H325
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W6028328
- Cited by
- 205
- References
- 0
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Topology and dimensions of pig coronary capillary network. https://app.cochat.ai/papers/10.1152/ajpheart.1994.267.1.h319
- The paper
- Kassab, G. S., & Fung, Y. C. (1994). Topology and dimensions of pig coronary capillary network. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1994.267.1.h319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.